Wnt signaling plays a central regulatory role across a remarkably diverse range of functions during embryonic development, including those involved in the formation of bone and cartilage. Wnt signaling continues to play a critical role in adult osteogenic differentiation of mesenchymal stem cells. Disruptions in this highly-conserved and complex system leads to various pathological conditions, including impaired bone healing, autoimmune diseases and malignant degeneration. For reconstructive surgeons, critically sized skeletal defects represent a major challenge. These are frequently associated with significant morbidity in both the recipient and donor sites. The Wnt pathway is an attractive therapeutic target with the potential to directly modulate stem cells responsible for skeletal tissue regeneration and promote bone growth, suggesting that Wnt factors could be used to promote bone healing after trauma. This review summarizes our current understanding of the essential role of the Wnt pathway in bone regeneration and repair.
Implants placed with high insertion torque (IT) typically exhibit primary stability, which enables early loading. Whether high IT has a negative impact on peri-implant bone health, however, remains to be determined. The purpose of this study was to ascertain how peri-implant bone responds to strains and stresses created when implants are placed with low and high IT. Titanium micro-implants were inserted into murine femurs with low and high IT using torque values that were scaled to approximate those used to place clinically sized implants. Torque created in peri-implant tissues a distribution and magnitude of strains, which were calculated through finite element modeling. Stiffness tests quantified primary and secondary implant stability. At multiple time points, molecular, cellular, and histomorphometric analyses were performed to quantitatively determine the effect of high and low strains on apoptosis, mineralization, resorption, and collagen matrix deposition in peri-implant bone. Preparation of an osteotomy results in a narrow zone of dead and dying osteocytes in peri-implant bone that is not significantly enlarged in response to implants placed with low IT. Placing implants with high IT more than doubles this zone of dead and dying osteocytes. As a result, peri-implant bone develops micro-fractures, bone resorption is increased, and bone formation is decreased. Using high IT to place an implant creates high interfacial stress and strain that are associated with damage to peri-implant bone and therefore should be avoided to best preserve the viability of this tissue.
BackgroundMetabolic syndrome (METS) is an increasingly prevalent but poorly understood clinical condition characterized by insulin resistance, glucose intolerance, dyslipidemia, hypertension, and obesity. Increased oxidative stress catalyzed by accumulation of iron in excess of physiologic requirements has been implicated in the pathogenesis of METS, but the relationships between cause and effect remain uncertain. We tested the hypothesis that phlebotomy-induced reduction of body iron stores would alter the clinical presentation of METS, using a randomized trial.MethodsIn a randomized, controlled, single-blind clinical trial, 64 patients with METS were randomly assigned to iron reduction by phlebotomy (n = 33) or to a control group (n = 31), which was offered phlebotomy at the end of the study (waiting-list design). The iron-reduction patients had 300 ml of blood removed at entry and between 250 and 500 ml removed after 4 weeks, depending on ferritin levels at study entry. Primary outcomes were change in systolic blood pressure (SBP) and insulin sensitivity as measured by Homeostatic Model Assessment (HOMA) index after 6 weeks. Secondary outcomes included HbA1c, plasma glucose, blood lipids, and heart rate (HR).ResultsSBP decreased from 148.5 ± 12.3 mmHg to 130.5 ± 11.8 mmHg in the phlebotomy group, and from 144.7 ± 14.4 mmHg to 143.8 ± 11.9 mmHg in the control group (difference -16.6 mmHg; 95% CI -20.7 to -12.5; P < 0.001). No significant effect on HOMA index was seen. With regard to secondary outcomes, blood glucose, HbA1c, low-density lipoprotein/high-density lipoprotein ratio, and HR were significantly decreased by phlebotomy. Changes in BP and HOMA index correlated with ferritin reduction.ConclusionsIn patients with METS, phlebotomy, with consecutive reduction of body iron stores, lowered BP and resulted in improvements in markers of cardiovascular risk and glycemic control. Blood donation may have beneficial effects for blood donors with METS.Trial registrationClinicalTrials.gov: NCT01328210Please see related article: http://www.biomedcentral.com/1741-7015/10/53
Patients with peripheral nerve injuries, especially severe injury, often face poor nerve regeneration and incomplete functional recovery, even after surgical nerve repair. This review summarizes treatment options of peripheral nerve injuries with current techniques and concepts and reviews developments in research and clinical application of these therapies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.