Purpose: To minimize ultrasound power use and surgical phaco time in illuminated chop cataract surgery.Methods: The charts of patients who underwent senile cataract surgery by a single surgeon were reviewed retrospectively. A conventional intracameral endoilluminator was used in a Stop & Chop group (n = 45), while an illuminated chopper was used in an illuminated chop (I-Chop) group (n = 71). EFX, a unitless value that roughly correlates with ultrasound energy during phacoemulsification, surgical phaco time, and changes in endothelial cell count were compared between the two groups and the ratio of zero phacoemulsification in the I-Chop group was evaluated.Results: EFX of the Stop & Chop and I-Chop groups was 18.08 ± 16.15 and 0.82 ± 3.53, respectively (p = 0.001), while the surgical phaco time was 185.08 ± 41.42 and 162.04 ± 49.65 seconds (p = 0.01). However, the endothelial loss did not differ in the two groups (7.03 ± 7.89 vs. 7.13 ± 9.47%, p = 0.76). In the I-Chop group, 56 (86%) eyes had zero phaco energy and patients with EFX >1 (n = 6) had more severe nuclear sclerosis grading (2.90 ± 0.71 vs. 4.5 ± 1.0; p = 0.001).Conclusions: The I-Chop group had lower EFX and shorter surgical phaco time than the Stop & Chop group. Illuminated chop using an illuminated chopper is one way to attain minimal phacoemulsification.
Purpose: To confirm that the phaco chop method using an illuminated chopper (iChopper; Oculight, Seongnam, Korea) can reduce cataract surgery complications, and that even beginners can safely and effectively perform phaco chop.Methods: We retrospectively analyzed the medical records of the first 30 phaco chop cases using illuminated chopper of four cataract surgeons. Four ophthalmologists had a variety of empirical backgrounds, from those who have experienced more than 10,000 cataract surgery, to beginners who have experienced 20 cataract surgery.Results: Of the total 120 eyes, two eyes (1.67%) had posterior capsule rupture. The chopping method was changed from phaco chop to stop and chop in three eyes (2.5%) including one eye with brown cataract with pseudoexofoliation syndrome and two eyes with nuclear opacity grade ≥5.Conclusions: The rates of posterior capsule rupture of phaco chop using an illuminated chopper were very low in four surgeons with various experiences and who became proficient shortly in phaco chop.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.