Detecting subsurface delamination is a difficult and vital task to maintain the durability and serviceability of concrete structure for its whole life cycle. The aim of this work was to obtain better knowledge of the effect of depth, heating time, and rebar on the detectability capacity of delamination. Experimental tests were carried out on a concrete specimen in the laboratory using Long Pulsed Thermography (LPT). Six halogen lamps and a long wavelength infrared camera with a focal plane array of 640 × 480 pixels were used as the heat source and infrared detector, respectively. The study focused on the embedded imitation delaminations with the size of 10 cm × 10 cm × 1 cm, located at depths varying from 1 to 8 cm. The signal-to-noise ratio (SNR) was applied as a criterion to assess the detectability of delamination. The results of this study indicate that as the provided heating time climbed, the SNR increased, and the defect could be identified more clearly. On the other hand, when using the same heating regime, a shallow delamination displayed a higher SNR than a deeper one. The moderate fall of the SNR in the case of imitating defect located below reinforced steel was also observed. The absolute contrast was monitored to determine the observation time, and the nondimensional prefactor k was empirically proposed to predict the depth of delamination. The mean absolute percentage error (MAPE) was used to quantitatively evaluate the difference between forecasted and real depth, which evaluation confirmed the high reliability of the estimated value of the prefactor k.
This study reveals that lumbar TDR using ProDisc-L is a safe and effective treatment for chronic back pain caused by lumbar DDD as assessed at more than 5 years postoperatively. Nevertheless, outcome scores were slightly, though significantly lower at last follow-up visits than at 1 and 2 years postoperatively. A longer-term follow-up study is warranted.
Bilateral locked facets at L4-5 without facet fracture is a rarely known disease. We present a case of a 37-year-old male patient diagnosed as traumatic L4-5 bilateral facets dislocation without facet fracture. We carried out open reduction, epidural hematoma removal, posterior interbody fusion. After surgery, we attained rapid improvement of the neurologic deficits and competent stabilization.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.