ObjectivesThe study measured the dose on body regions that were not shielded to protect from radiation exposure during the general procedure, with the goal of providing basic radiation dose data for radiological technologists who perform the radiographic examination.Materials and methodsShooting parts with the phantom were similar to human tissues using general shooting equipment in the general examination room. The scattered rays were measured with the ion chamber. The hand received the highest average radiation dose and the kidney the lowest. The same pattern was evident for the average equivalent dose. The available daily shooting was highest in the anterior/posterior skull, followed by the posterior/anterior chest, abdomen, anterior/posterior spine and extremities.ResultsThe daily available numbers for the eye were lower than other body regions (6-times, 4-times, 26-times, 3-times and 121-times) and the numbers on the foot were higher than for other regions (73-times, 48-times, 263-times, 39-times and 702-times).ConclusionsRadiation should be thoroughly blocked by the apron to protect the radiological technologist from the radiation exposure, the proper distance from the irradiation source should be maintained exposure is inevitable and the exposure dose and working environment shall be regularly assessed to ensure minimal exposure dose of the radiological technologist in accordance with the International Commission on Radiological Protection recommendation.
This study evaluates the change of computer tomography (CT) number in the case of the metal artifact reduction (MAR) algorithm, using the phantom. The images were obtained from dual CT using a gammex 467 tissue characterization phantom, which is similar to human tissues. The test method was performed by dividing pre and post MAR algorithm and measured CT values of nonmagnetic materials within the phantom. In addition, the changes of CT values for each material were compared and analyzed after measuring CT values up to 140 keV, using the spectral HU curve followed by CT scan. As a result, in the cases of N rod (trabecular bone) and E rod (trabecular bone), the CT numbers decreased as keV increasing but were constant above 90 keV. In the cases of I rod (dense bone) and K rod (dense bone), the CT numbers also decreased as keV increased but were uniform above 90 keV. The CT numbers from 40 keV to 140 keV were consistent in the cases of J rod (liver), D rod (liver), L rod (muscle), and F rod (muscle). For A rod (adipose), G rod (adipose), B rod (breast) and O rod (breast), the CT numbers increased as keV increased but were constant after 90 keV. The CT numbers from 40 keV to 140 keV were consistent in the cases of C rod (lung (exhale)), P rod (lung (exhale)), M rod (lung (inhale)) and H rod (lung (exhale)). Conclusively, because dual CT exhibits no changes in image quality and is able to analyze nonmagnetic materials by measuring the CT values of various materials, it will be used in the future as a useful tool for the diagnosis of lesions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.