Measurement of intracranial pressure (ICP) is crucial in the management of many neurological conditions. However, due to the invasiveness, high cost, and required expertise of available ICP monitoring techniques, many patients who could benefit from ICP monitoring do not receive it. As a result, there has been a substantial effort to explore and develop novel noninvasive ICP monitoring techniques to improve the overall clinical care of patients who may be suffering from ICP disorders. This review attempts to summarize the general pathophysiology of ICP, discuss the importance and current state of ICP monitoring, and describe the many methods that have been proposed for noninvasive ICP monitoring. These noninvasive methods can be broken down into four major categories: fluid dynamic, otic, ophthalmic, and electrophysiologic. Each category is discussed in detail along with its associated techniques and their advantages, disadvantages, and reported accuracy. A particular emphasis in this review will be dedicated to methods based on the use of transcranial Doppler ultrasound. At present, it appears that the available noninvasive methods are either not sufficiently accurate, reliable, or robust enough for widespread clinical adoption or require additional independent validation. However, several methods appear promising and through additional study and clinical validation, could eventually make their way into clinical practice.
Objective One goal of neuromorphic engineering is to create “realistic” robotic systems that interact with the physical world by adopting neuromechanical principles from biology. Critical to this is the methodology to implement the spinal circuitry responsible for the behavior of afferented muscles. At its core, muscle afferentation is the closed-loop behavior arising from the interactions among populations of muscle spindle afferents, alpha and gamma motoneurons, and muscle fibers to enable useful behaviors. Approach We used programmable Very-Large-Scale-Circuit (VLSI) hardware to implement simple models of spiking neurons, skeletal muscles, muscle spindle proprioceptors, alpha-motoneuron recruitment, gamma motoneuron control of spindle sensitivity, and the monosynaptic circuitry connecting them. This multi-scale system of populations of spiking neurons emulated the physiological properties of a pair of antagonistic afferented mammalian muscles (each simulated by 1,024 alpha- and gamma-motoneurones) acting on a joint via long tendons. Main results This integrated system was able to maintain a joint angle, and reproduced stretch reflex responses even when driving the nonlinear biomechanics of an actual cadaveric finger. Moreover, this system allowed us to explore numerous values and combinations of gamma-static and gamma-dynamic gains when driving a robotic finger, some of which replicated some human pathological conditions. Lastly, we explored the behavioral consequences of adopting three alternative models of isometric muscle force production. We found that the dynamic responses to rate-coded spike trains produce force ramps that can be very sensitive to tendon elasticity, especially at high force output. Significance Our methodology produced, to our knowledge, the first example of an autonomous, multi-scale, neuromorphic, neuromechanical system capable of creating realistic reflex behavior in cadaveric fingers. This research platform allows us to explore the mechanisms behind healthy and pathological sensorimotor function in the physical world by building them from first principles, and it is a precursor to neuromorphic robotic systems.
This paper describes a new subspace-based algorithm for the identification of Hammerstein systems. It extends a previous approach which described the Hammerstein cascade by a state-space model and identified it with subspace methods that are fast and require little a priori knowledge. The resulting state-space models predict the system response well but have many redundant parameters and provide limited insight into the system since they depend on both the nonlinear and linear elements. This paper addresses these issues by reformulating the problem so that there are many fewer parameters and each parameter is related directly to either the linear dynamics or the static nonlinearity. Consequently, it is straightforward to construct the continuous-time Hammerstein models corresponding to the estimated state-space model. Simulation studies demonstrated that the new method performs better than other well-known methods in the nonideal conditions that prevail during practical experiments. Moreover, it accurately distinguished changes in the linear component from those in the static nonlinearity. The practical application of the new algorithm was demonstrated by applying it to experimental data from a study of the stretch reflex at the human ankle. Hammerstein models were estimated between the velocity of ankle perturbations and the EMG activity of triceps surae for voluntary contractions in the plantarflexing and dorsiflexion directions. The resulting models described the behavior well, displayed the expected unidirectional rate sensitivity, and revealed that both the gain of the linear element and the threshold of the nonlinear changed with contraction direction.
SDSS will be a valuable tool for studying joint stiffness under functionally important conditions. It has important clinical implications for the diagnosis, assessment, objective quantification, and monitoring of neuromuscular diseases that change the muscle tone.
Objective We studied the fundamentals of muscle afferentation by building a neuro-mechano-morphic system actuating a cadaveric finger. This system is a faithful implementation of the stretch reflex circuitry. It allowed the systematic exploration of the effects of different fusimotor drives to the muscle spindle on the closed-loop stretch reflex response. Approach As in Part I of this work, sensory neurons conveyed proprioceptive information from muscle spindles (with static and dynamic fusimotor drive) to populations of α-motor neurons (with recruitment and rate coding properties). The motor commands were transformed into tendon forces by a Hill-type muscle model (with activation-contraction dynamics) via brushless DC motors. Two independent afferented muscles emulated the forces of flexor digitorum profundus and the extensor indicis proprius muscles, forming an antagonist pair at the metacarpophalangeal joint of a cadaveric index finger. We measured the physical response to repetitions of bidirectional ramp-and-hold rotational perturbations for 81 combinations of static and dynamic fusimotor drives, across four ramp velocities, and three levels of constant cortical drive to the α-motor neuron pool. Results We found that this system produced responses compatible with the physiological literature. Fusimotor and cortical drives had nonlinear effects on the reflex forces. In particular, only cortical drive affected the sensitivity of reflex forces to static fusimotor drive. In contrast, both static fusimotor and cortical drives reduced the sensitivity to dynamic fusimotor drive. Interestingly, realistic signal-dependent motor noise emerged naturally in our system without having been explicitly modeled. Significance We demonstrate that these fundamental features of spinal afferentation sufficed to produce muscle function. As such, our neuro-mechano-morphic system is a viable platform to study the spinal mechanisms for healthy muscle function — and its pathologies such as dystonia and spasticity. In addition, it is a working prototype of a robust biomorphic controller for compliant robotic limbs and exoskeletons.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.