Average T- and C-levels for the Nucleus 24 Contour patients were considerably lower than those using the Nucleus 24 (CI24M). A total of 85 patients had measurable hearing preoperatively at two or more audiometric frequencies in the ear implanted. Of these patients 41 (48%) had measurable hearing at one or more frequencies and 32 (38%) had measurable hearing at two or more frequencies postoperatively. In general, surgeons found the Nucleus 24 Contour easy to insert and were pleased with the design features of the device. The downsized receiver/stimulator (of the Nucleus 24 Contour) required less drilling than the Nucleus 24, reducing surgical time, as well as making the Contour better suited for implantation in those with small skull sizes (e.g., small children and infants). After 3 mo of device use, mean open-set speech perception in quiet and in noise was significantly better than preoperative performance on all test measures. Patients using the ACE strategy had significantly better mean scores for all measures than patients using SPEAK. Only two patients preferred to use the CIS coding strategy. CONCLUSIONS The results presented in this article demonstrated that the design objectives of the Nucleus 24 Contour were met. Namely, results from this study, together with insertion studies, were consistent with perimodiolar placement using an implant design that the majority of surgeons found easy to insert with relatively minimal trauma. Reduced T- and C-levels were observed with Contour patients when compared with patients using the Nucleus 24 with the straight array, consistent with perimodiolar placement. A survey of surgeons participating in the clinical trial indicated easier, or equally easy, insertion of the Contour array, compared with previous Nucleus products as well as other manufacturers' devices, without the use of additional insertion tools or array positioners. Postoperatively, 46% of patients with preoperative residual hearing maintained some level of unaided hearing postoperatively, suggesting atraumatic insertion of the Nucleus 24 Contour electrode array. It is worth noting that all 216 patients implanted during this study had full insertions of their Contour electrode arrays. High levels of open-set speech perception in quiet and in noise were achieved and patients using the ACE strategy had significantly better mean scores for all measures than patients using SPEAK. Only two patients preferred to use the CIS coding strategy.
A study is reported of the effect of early visual experience on the development of auditory space perception. The spatial hearing of thirty-five children with visual disabilities (twenty-two with congenital total blindness) was compared with that of eighteen sighted children and seventeen sighted adults. The tests provided a comprehensive assessment of spatial-hearing ability, including psychophysical estimates of spatial resolution in the horizontal, vertical, and distance dimensions, as well as measures of reaching and walking to the locations of sound sources. The spatial hearing of the children with visual disabilities was comparable to or somewhat better than that of the sighted children and adults. This pattern held even when the group with visual disabilities was restricted to those children with congenital total blindness; in fact, some of those children had exceptionally good spatial hearing. These findings imply that the developmental calibration of human spatial hearing is not dependent on a history of visual experience. It seems likely that this calibration arises from the experience of changes in sound-localization cues arising from self-motion, such as turning the head or walking. As a practical matter, orientation and mobility instructors may reasonably assume that individuals with visual disabilities can use their hearing effectively in day-to-day travel situations.
The minimum age for cochlear implantation has been reduced to 12 months in an effort to provide auditory stimulation to children with hearing loss during early development. Because behavioral measures in such young children are limited, objective measures such as the electrically evoked compound action potential (EAP) from the auditory nerve are needed to facilitate measurement of stimulation level requirements. We assessed EAPs recorded by the Nucleus 24 neural response telemetry (NRT) system in children who underwent implantation between 12 and 24 months of age. We recorded EAPs in 37 such children (mean age at implantation, 18.1 ± 3.6 months). The EAPs were of large amplitude, and thresholds fell between behavioral T and C levels. A correction factor applied to EAP thresholds provided useful predictions of T levels. The EAPs can be used to ensure that even very young children receive auditory stimulation with their cochlear implants upon device activation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.