Despite the benefits associated with the use of food waste (FW), there are mixed consumer perceptions regarding pork quality harvested from pigs fed FW. Twenty crossbred pigs were selected for the present study. Ten pigs were fed a conventional diet (control group), and the other 10 pigs were given a conventional diet and FW (FW group) during different growth stages. Meat quality in the FW group showed deteriorative qualities with higher lightness and yellowness synonymous to pale soft exudative meat. Drip loss in the experimental group was significantly higher than that in the control group (p<0.01). The contents of polyunsaturated fatty acids in the FW group were higher and those of saturated and monounsaturated fatty acids were lower than those in the control group. The contents of thiobarbituric acid were significantly different between the control and FW groups (p<0.05). There was also a significant difference between the control and FW groups in terms of off-flavor (p<0.05) after sensory evaluation. To conclude, the off-flavor noted, including other inferior pork quality traits, in the FW group implies that FW should not be used as swine feed.
Although laparoscopic surgery had been performed in clinical practice for over 30 years, there has not been much improvement on instruments. Several articulating laparoscopic instruments have been developed including the robotic system. A new multi-degree of freedom (DOF) articulating laparoscopic device has been developed. We compared the ability to perform challenging sutures between the new device and the robotic system. Methods: Five experienced surgeons with over 100 laparoscopic surgery cases performed the suture task with both instruments. Everyone was new at articulating instruments including a robotic system. The suturing task consisted of two vertical sutures, downward and upward vertical direction. The duration of needle grabbing, first surgical tie, square tie, and the final reverse tie was measured. Results: When doing the downward suture, the median time to complete the suture was 127 vs. 136 seconds for ArtiSential ® and the robot, respectively (p=0.754). Other measurements such as needle grabbing, first tie, second tie and final knot did not show any significant difference between the two instruments. Upward suture also did not show a significant difference. The total completion time was 127 vs. 112 seconds for for ArtiSential ® and the robot, respectively (p=0.675). Time taken in each interval did not show any significant difference. Conclusion: Both instruments performed the suturing tasks with no difference in duration. ArtiSential ® can be mixed up with usual instruments. Surgeons can choose any device, but when articulation is needed, ArtiSential ® could be an alternative choice to the robotic system.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.