The Gippsland Water Factory (GWF), owned and operated by Gippsland Water in south eastern Australia, is a 35,000 m 3 /day water reclamation facility which treats 16,000 m 3 /day of domestic wastewater and 19,000 m 3 /day of industrial (pulp and paper) wastewater through parallel membrane-bioreactor (MBR)-based treatment trains prior to discharge to the Pacific Ocean via the Regional Outfall Sewer. A portion of the domestic train MBR effluent is further treated through a chloramination and reverse osmosis (RO) system for reclamation, as needed to augment the regional water supply, and is supplied to Australia Paper, the source of the industrial wastewater treated at the GWF. While use of the MBR/RO combination for water reclamation is expected to provide advantages, little full-scale experience exists. Consequently, this paper reports operational and performance results for the first four years of operation for the MBR/RO water reclamation train.Details are provided, not only on process performance, but also on the resolution of equipment and plant performance issues along with ongoing plant optimization. On the basis of these operating results, it is concluded that the combination of MBR and RO is a reliable and robust option for producing high-quality reclaimed water from municipal wastewater.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.