Background.
Recently, a new liver allocation policy called the acuity circles (AC) framework was implemented to decrease geographic disparities in transplant metrics across donor service areas. Early analyses have examined the changes in outcomes because of the AC policy. However, perceptions among transplant surgeons and staff regarding the new policy remain unknown.
Methods.
A 28-item survey was sent to division chiefs and surgical directors of liver transplantation across the United States. Questions assessed the respondents’ perceptions regarding center-level metrics and staff satisfaction. We used Organ Procurement and Transplantation Network data to study differences in allocation between the pre-AC implementation period (2019) and the post-AC implementation period (2020–2021).
Results.
A total of 40 participants completed this ongoing survey study. Most responses were from region 8 (13%), region 10 (15%), and region 11 (13%). Sixty-three percent of respondents stated that the wait time for a suitable offer for recipients with model of end-stage liver disease score <30 has decreased, whereas 50% stated that wait time for a suitable offer for recipients with model of end-stage liver disease score >30 has increased. However, most respondents (75%) felt that the average cost per transplant had increased and that the rate of surgical complications and 1-y graft survival had remained the same. In most states, an observable decrease in in-state liver transplantations occurred each year between 2019 and 2021. In addition, most allocation regions reported an increase in donations after circulatory deaths between 2019 and 2021.
Conclusions.
Perceptions of the new AC policy among liver transplant surgeons in the United States remain mixed, highlighting the potential strengths and concerns regarding its future impact. Further studies should assess the effects of the AC policy on clinical outcomes and liver transplantation access.
Background/Aims: Upper gastrointestinal bleeding (UGIB) is a life-threatening condition that necessitates early identification and intervention and is associated with substantial morbidity, mortality, and socioeconomic burden. However, several diagnostic challenges remain regarding risk stratification and the optimal timing of endoscopy. The PillSense System is a noninvasive device developed to detect blood in patients with UGIB in real time. This study aimed to assess the safety and performance characteristics of PillSense using a simulated bleeding model.Methods: A preclinical study was performed using an in vivo porcine model (14 animals). Fourteen PillSense capsules were endoscopically placed in the stomach and blood was injected into the stomach to simulate bleeding. The safety and sensitivity of blood detection and pill excretion were also investigated.Results: All the sensors successfully detected the presence or absence of blood. The minimum threshold was 9% blood concentration, with additional detection of increasing concentrations of up to 22.5% blood. All the sensors passed naturally through the gastrointestinal tract.Conclusions: This study demonstrated the ability of the PillSense System sensor to detect UGIB across a wide range of blood concentrations. This ingestible device detects UGIB in real time and has the potential to be an effective tool to supplement the current standard of care. These favorable results will be further investigated in future clinical studies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.