A CT based selection strategy is a valid preoperative tool for evaluation of giant cell tumor. Further, for curettage these lesions are better approached through the site of cortical break, irrespective of standard approaches, so that adequate soft tissue clearance can be achieved.
Purpose: To test the significance of calcar referenced tip-apex distance (CalTAD) and the length of anti-rotation screw (AR screw) as predictors for failure after biaxial cephalomedullary (CM) nailing of intertrochanteric fractures. Methods: We retrospectively reviewed 190 consecutive fractures that had undergone biaxial CM nailing. Of these, 67 met the inclusion criteria of a non-pathological fracture with a minimum of 90 days radiological follow-up (mean 458 days; 91 days to 4.9 years). Results: The overall failure rate was 15% (10 of 67). Failure was associated with a higher CalTAD in most of the patients (13%, p < 0.001). A higher tip-apex distance (TAD) was not significantly associated with failure (p ¼ 0.132), when the CalTAD was less than 25 mm. When the AR screw length exceeded a line connecting the tip of the nail and the lag screw, screw cutout occurred only in one patient (p ¼ 0.095). Conclusion: Our data provide the first reported clinical evidence that the CalTAD is a better predictor of cutout in biaxial CM nailing than TAD measurement. However, the length of anti-rotational element does not seem to be an independent predictor of CM nailing failure.
Migration of wires or pins around the shoulder is a known complication, though their migration within the chest is uncommon. We report an unusual case of hydropneumothorax due to migration of a bent Kirschner wire from the right proximal humerus in a 63 year-old man. We reviewed his clinical history, physical examination, imaging findings, surgical method and outcome. We also reviewed the literature on orthopaedic wire migration and latest technique in removal of the wires. Chest radiographs and chest computerized tomography are useful in detection and diagnosis of this disorder. Regular radiographic follow-up is needed for patients with internal fixation devices; any fractured or migrated pins or wires must be removed immediately to prevent dangerous complications. It is always important to remove the wires at the end of the treatment. Early removal of fixation wires and regular follow-up if wires are retained are essential to prevent serious complications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.