BackgroundA prototype magnetic resonance image (MRI)-conditional robot was developed for navigating a high-intensity focused ultrasound (HIFU) system in order to treat prostate cancer transrectally.Materials and methodsThe developed robotic device utilizes three PC-controlled axes: a linear axis for motion along the rectum, an angular axis for rotation in the rectum, and a linear axis to lift the robot up and down. Experiments with the system were performed in a 1.5-T MRI system using gel phantoms.ResultThe robot was successfully operated in a 1.5-T clinical MRI system. The effect of piezoelectric motors and optical encoders was quantified based on the reduction of signal to noise ratio. Discrete and overlapping lesions were created accurately by moving the HIFU transducer with the robotic device.ConclusionAn MRI-conditional HIFU robot was developed which can create controlled thermal lesions under MRI guidance. The intention is to use this robot transrectally in the future for the treatment of prostate cancer.
Objective A prototype magnetic resonance imaging (MRI)-compatible positioning device was used to move an MRIguided high intensity focused ultrasound (HIFU) transducer. The positioning device has three user-controlled degrees of freedom that allow access to various targeted lesions. Materials and methods The positioning device was designed and fabricated using construction materials selected for compatibility with high magnetic fields and fast switching magnetic field gradients encountered inside MRI scanners. The positioning device incorporates only MRI compatible materials such as piezoelectric motors, plastic sheets, brass screws, plastic pulleys and timing belts. The HIFU/MRI system includes the multiple subsystems (a) HIFU system, (b) MR imaging, (c) Positioning device (robot) and associate drivers, (d) temperature measurement, (e) cavitation detection, (f) MRI compatible camera, and (g) Soft ware. Results The MRI compatibility of the system was successfully demonstrated in a clinical high-field MRI scanner. The ability of the robot to accurately move the transducer thus creating discrete and overlapping lesions in biological tissue was tested successfully. Conclusion A simple, cost effective, portable positioning device has been developed which can be used in virtually C. Damianou 路 N. Milonas Frederick Institute of Technology (FIT), Limassol, Cyprus any clinical MRI scanner since it can be sited on the scanner's table. The propagation of HIFU can use either a lateral or superior-inferior approach. Discrete and large lesions were created successfully with reproducible results.
In this paper, magnetic resonance imaging (MRI) is investigated for monitoring small and large lesions created by high-intensity focused ultrasound (HIFU) in freshly excised lamb brain and in rabbit brain in vivo. A single-element spherically focused transducer of 5 cm diameter, focusing at 10 cm and operating at 1 MHz was used. A prototype MRI-compatible positioning device that is used to navigate the transducer is described. The effects of HIFU were investigated using T1-W and T2-W fast spin echo (FSE) and fluid-attenuated inversion recovery (FLAIR). T2-W FSE and FLAIR show better anatomical details within the brain than T1-W FSE, but with T1-W FSE, the contrast between lesion and brain is higher for both thermal and bubbly lesions. The best contrast between lesion and brain with T1-W FSE is obtained with TR above 500 ms, whereas with T2-W FSE, the best contrast is observed between 40 and 60 ms. The maximum contrast to noise ratio (CNR) measured with T1-W FSE was approximately 20. With T2-W FSE, the corresponding CNR was approximately 12. With this system, we were able to create large lesions (by producing overlapping lesions), and it was possible to monitor these lesions with MRI with excellent contrast. The length of the lesions in vivo brain was much higher than the length in vitro, indicating that the penetration in the in vitro brain is limited, possibly by reflection due to trapped bubbles in the blood vessels. This paper demonstrates that HIFU has the potential to treat brain tumors in humans. This could be done either using a single-element transducer with a frequency around 1 MHZ or using a multi-element transducer.
In this paper the goal was to measure the contrast to noise ratio (CNR) of fast spin echo (FSE) magnetic resonance imaging (MRI) sequences in detecting thermal lesions created by high intensity focused ul-trasound (HIFU) in rabbit kidney, liver, heart, and brain and lamb pancreas. A spherically focused transducer was used which is navigated inside MRI by a custom made positioning device. A simple simu-lation model was developed which predicts the CNR for the two FSE MRI sequences. The maximum con-trast measured with T1-W FSE ranges from 10 to 25. For all 5 tissues of interest if one uses TR between 400 and 500 ms the contrast is maximized. The T1 and T2 value of lesion depends strongly on the host tissue and is always lower than the host tissue. The greater the difference in T1 value, the greater the CNR. The simulated model for predicting the CNR was proven successful. The CNR measured with T2-W FSE varies between 12 and 15 for all 5 tissues. With T2-W FSE if one uses TE between 40 and 50 ms, the contrast is maximized
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations鈥揷itations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.