Single nucleotide polymorphism (SNP) data generated with microarray technologies have been used to solve murder cases via investigative leads obtained from identifying relatives of the unknown perpetrator included in accessible genomic databases, referred to as investigative genetic genealogy (IGG). However, SNP microarrays were developed for relatively high input DNA quantity and quality, while SNP microarray data from compromised DNA typically obtainable from crime scene stains are largely missing. By applying the Illumina Global Screening Array (GSA) to 264 DNA samples with systematically altered quantity and quality, we empirically tested the impact of SNP microarray analysis of deprecated DNA on kinship classification success, as relevant in IGG. Reference data from manufacturer-recommended input DNA quality and quantity were used to estimate genotype accuracy in the compromised DNA samples and for simulating data of different degree relatives. Although stepwise decrease of input DNA amount from 200 nanogram to 6.25 picogram led to decreased SNP call rates and increased genotyping errors, kinship classification success did not decrease down to 250 picogram for siblings and 1st cousins, 1 nanogram for 2nd cousins, while at 25 picogram and below kinship classification success was zero. Stepwise decrease of input DNA quality via increased DNA fragmentation resulted in the decrease of genotyping accuracy as well as kinship classification success, which went down to zero at the average DNA fragment size of 150 base pairs. Combining decreased DNA quantity and quality in mock casework and skeletal samples further highlighted possibilities and limitations. Overall, GSA analysis achieved maximal kinship classification success from 800-200 times lower input DNA quantities than manufacturer-recommended, although DNA quality plays a key role too, while compromised DNA produced false negative kinship classifications rather than false positive ones.
This paper discusses the impact of conventional RF parameters of DAB front-ends (i.e. 3rd order 2-tone intermodulation ratio, noise figure, phase noise, frequency and phase response, adjacent channel and image frequency selection) on the bit error rate (BER) that is obtainable from DAB receivers. The results of theoretical study are compared with experimental results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.