The purpose of this phantom study was to investigate the feasibility of dose reduction with hybrid iterative reconstruction, with and without a noise power spectrum (NPS) model, using both quantitative and qualitative evaluations. Standard dose (SD), three‐quarter dose (TQD), and half‐dose (HD) of radiation were used. Images were reconstructed with filtered back projection (FBP), adaptive iterative dose reduction 3D (AIDR 3D) (MILD, STR), and AIDR 3D enhanced (eAIDR 3D) (eMILD, eSTR). An NPS analysis, task‐based modulation transfer function (MTF task) analysis, and comparisons of low‐contrast detectability and image texture were performed. Although the eAIDR 3D had a higher NPS value in the high‐frequency range and improved image texture and resolution as compared with AIDR 3D at the same radiation dose and iteration levels, it yielded higher noise than AIDR 3D. Additionally, although there was no statistically significant difference between SD‐FBP and the TQD series in the comparison of the mean area under the curve (AUC), the mean AUC was statistically significantly different between SD‐FBP and the HD series. NPS values in the high‐frequency range, 10% MTF task values, low‐contrast detectability, and image textures of TQD‐eMILD were comparable to those of SD‐FBP. Our findings suggested that using eMILD can reduce the radiation dose by 25%, while potentially maintaining diagnostic performance, spatial resolution, and image texture; this could support selecting the appropriate protocol in a clinical setting.
Sixteen-slice MDCT has a potential for noninvasive quantitative evaluation of stenosis in coronary arteries.
To compare the radiation dose and image noise of nonenhanced CT scans performed at 80, 100, and 120 kVp with tube current modulation (TCM) we used anthropomorphic phantoms of newborn, 1‐year‐old, and 5‐year‐old children. The noise index was set at 12. The image noise in the center of the phantoms at the level of the chest and abdomen was measured within a circumscribed region of interest. We measured the doses in individual tissues or organs with radio‐photoluminescence glass dosimeters for each phantom. Various tissues or organs were assigned and the radiation dose was calculated based on the international commission on radiological protection definition. With TCM the respective radiation dose at tube voltages of 80, 100, and 120 was 29.71, 31.60, and 33.79 mGy for the newborn, 32.00, 36.79, and 39.48 mGy for the 1‐year‐old, and 32.78, 38.11, and 40.85 mGy for the 5‐year‐old phantom. There were no significant differences in the radiation dose among the tube voltages and phantoms (P > 0.05). Our comparison of the radiation dose using anthropomorphic phantoms of young children showed that the radiation dose of nonenhanced CT performed at different tube voltages with TCM was not significantly different.
The purpose of this study was to compare renal cyst pseudoenhancement between virtual monochromatic spectral (VMS) and conventional polychromatic 120-kVp images obtained during the same abdominal computed tomography (CT) examination and among images reconstructed using filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR), and model-based iterative reconstruction (MBIR).Our institutional review board approved this prospective study; each participant provided written informed consent. Thirty-one patients (19 men, 12 women; age range, 59–85 years; mean age, 73.2 ± 5.5 years) with renal cysts underwent unenhanced 120-kVp CT followed by sequential fast kVp-switching dual-energy (80/140 kVp) and 120-kVp abdominal enhanced CT in the nephrographic phase over a 10-cm scan length with a random acquisition order and 4.5-second intervals. Fifty-one renal cysts (maximal diameter, 18.0 ± 14.7 mm [range, 4–61 mm]) were identified. The CT attenuation values of the cysts as well as of the kidneys were measured on the unenhanced images, enhanced VMS images (at 70 keV) reconstructed using FBP and ASIR from dual-energy data, and enhanced 120-kVp images reconstructed using FBP, ASIR, and MBIR. The results were analyzed using the mixed-effects model and paired t test with Bonferroni correction.The attenuation increases (pseudoenhancement) of the renal cysts on the VMS images reconstructed using FBP/ASIR (least square mean, 5.0/6.0 Hounsfield units [HU]; 95% confidence interval, 2.6–7.4/3.6–8.4 HU) were significantly lower than those on the conventional 120-kVp images reconstructed using FBP/ASIR/MBIR (least square mean, 12.1/12.8/11.8 HU; 95% confidence interval, 9.8–14.5/10.4–15.1/9.4–14.2 HU) (all P < .001); on the other hand, the CT attenuation values of the kidneys on the VMS images were comparable to those on the 120-kVp images.Regardless of the reconstruction algorithm, 70-keV VMS images showed a lower degree of pseudoenhancement of renal cysts than 120-kVp images, while maintaining kidney contrast enhancement comparable to that on 120-kVp images.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.