We examined the incidence of long P wave duration in lead II and increased P terminal force in lead V1 (PTFV1), and their relationship to electrophysiological findings of atrial muscle in 34 patients with sick sinus syndrome (SSS). Patients were divided into three groups: Group I, consisting of 20 patients with various cardiac arrhythmias other than SSS and paroxysmal atrial fibrillation (PAF) who served as controls; Group II, consisting of 18 patients with SSS but without PAF; and Group III consisted of 16 patients with SSS and PAF. P wave duration was significantly longer in Group III (122 +/- 11 ms, mean +/- SD, P < 0.0001) and Group II (111 +/- 15 ms, P < 0.002) than in Group I (98 +/- 10 ms). PTFV1 was greater in Group III (0.052 +/- 0.025 ms) than in Group I (0.028 +/- 0.011 ms, P < 0.05). P wave duration and PTFV1 had significantly and/or borderline correlations with longest duration of right atrial electrograms (r = 0.84, P < 0.0001 and 0.47, P < 0.02, respectively), maximal number of fragmented deflections of atrial electrograms (r = 0.69, P < 0.0001 and r = 0.51, P < 0.02, respectively), repetitive atrial firing zone (RAFZ) (r = 0.81, P < 0.0001 and 0.48, P < 0.05, respectively) and fragmented atrial activity zone (FAAZ)(r = 0.53, P < 0.01 and r = 0.45, P = 0.06, respectively). We concluded that long P wave duration and increased PTFV1 are electrocardiographic indicators for coexistence of electrophysiological abnormalities in the atria in SSS without recognizable heart disease.
The purpose of the study was to compare the effects of DDD pacing with optimal AV delay and AAI pacing on the systolic and diastolic performance at rest in patients with prolonged intrinsic AV conduction (first-degree AV block). We studied 17 patients (8 men, aged 69 +/- 9 years) with dual chamber pacemakers implanted for sick sinus syndrome in 15 patients and paroxysmal high degree AV block in 2 patients. Aortic flow and mitral flow were evaluated using Doppler echocardiography. Study protocol included the determination of the optimal AV delay in the DDD mode and comparison between AAI and DDD with optimal AV delay for pacing rate 70/min and 90/min. Stimulus-R interval during AAI (ARI) was 282 +/- 68 ms for rate 70/min and 330 +/- 98 ms for rate 90/min (P < 0.01). The optimal AV delay was 159 +/- 22 ms. AV delay optimization resulted in an increase of an aortic flow time velocity integral (AFTVI) of 16% +/- 9%. At rate 70/min the patients with ARI < or = 270 ms had higher AFTVI in AAI than in DDD (0.214 +/- 0.05 m vs 0.196 +/- 0.05 m, P < 0.01), while the patients with ARI > 270 ms demonstrated greater AFTVI under DDD compared to AAI (0.192 +/- 0.03 m vs 0.166 +/- 0.02 m, P < 0.01). At rate 90/min AFTVI was higher during DDD than AAI (0.183 +/- 0.03 m vs 0.162 +/- 0.03 m, P < 0.01). Mitral flow time velocity integral (MFTVI) at rate 70/min was higher in DDD than in AAI (0.189 +/- 0.05 m vs 0.173 +/- 0.05 m, P < 0.01), while at rate 90/min the difference was not significant in favor of DDD (0.149 +/- 0.05 m vs 0.158 +/- 0.04 m). The results suggest that in patients with first-degree AV block the relative impact of DDD and AAI pacing modes on the systolic performance depends on the intrinsic AV conduction time and on pacing rate.
Our data indicate that the electrophysiological features of paroxysmal AF associated with hyperthyroidism are essentially different from those of lone paroxysmal AF. In patients with paroxysmal AF and hyperthyroidism, a shortening of the refractory period in association with a facilitation of the atrial CD could be expected to increase the propensity for AF, and a pre-existent arrhythmogenic substrate might not be essential to the genesis of AF. These findings suggest that the agents that prolong the atrial ERP are effective against AF in patients with hyperthyroidism.
This paper presents the power density developments of high-power isolated dc-dc converter to be utilized in a higher voltage direct-current (HVDC) powersupply system of a data center. This technique results in a prototype of dc-dc converter unit which is smaller by factor of ten when compared with the conventional one, and the area of power-supply system becomes much smaller than before. Consequently, the cooling power for this power-supply system is saved and both the energy and the space saving are available.In order to realize a prototype of the high-power isolated dcdc converter, the switching power devices composed of a hybrid pair of Si-CoolMOS and SiC-SBD are utilized and operated in a driving pattern of hard switching with a frequency of 200kHz. As a result, an isolated dc-dc converter with the input/output voltage of 400V/400V, a rating power of 5kW, and a high power density of 10W/cm 3 has been fabricated. The experimental confirmation was reported and the surge problems due to diode recovery difficulties mentioned before was solved.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.