Background In total knee arthroplasty (TKA) using the modified gap technique, the soft-tissue balance is measured after osteotomy of the distal femur and proximal tibia (conventional bone gap). However, after osteotomy, the flexion gap size during 90° knee flexion may be larger than that observed after implantation. The tension of the lateral compartment during 90° flexion may also be reduced after osteotomy of the distal femur. We manufactured a distal femoral trial component to reproduce the condition after implantation and prior to posterior condyle osteotomy. This study aimed to evaluate the effect of the trial component on the flexion gap. Methods This prospective study included 21 consecutive patients aged 78 years with medial osteoarthritis who underwent cruciate-retaining TKA between February 2017 and March 2018. The postoperative flexion gap size and inclination during 90° flexion were compared between cases with and without the trial component. Results The mean joint gap size with the trial component (13.4 ± 0.80 mm) was significantly smaller than that without the trial component (14.7 ± 0.84 mm). The mean gap inclination angle with the trial component (3.7° ± 0.62°) was significantly smaller than that without the trial component (5.5° ± 0.78°). Conclusions In the present study, the joint gap size and medial tension were significantly reduced after the trial component had been set. Accurate measurement of the soft-tissue balance is an important factor in the modified gap technique, and this method using a distal femoral trial component can offer better outcomes than those achieved with conventional methods.
Purpose A distal femoral trial component was manufactured, and flexion gap size and inclination were evaluated with or without the distal femoral trial component in total knee arthroplasty (TKA). This study aimed to evaluate the effect of the distal femoral trial component on flexion gap size and joint inclination in posterior-stabilized (PS)-TKA. Materials and methods A total of 84 patients with medial osteoarthritis who underwent mobile-bearing PS-TKA using modified gap techniques were included in this retrospective study. The flexion gap size and inclination before and after setting the distal femoral trial component were evaluated and compared with the final gap size and inclination. Results The joint gap size and inclination were significantly lower in those with than in those without the distal femoral trial component (P = 0.005, P < 0.001). The final gap size and inclination were similar to the gap size and inclination with the distal trial component (P = 0.468, P = 0.158). Conclusions The joint gap size and medial tension in PS-TKA were significantly reduced after setting the distal femoral trial component. The flexion gap measured using the distal femoral trial component was similar to that when the final trial component was set. To more accurately perform the gap technique TKA, the flexion gap should be measured using the distal femoral trial component.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.