A contrast-enhanced, gradient-echo 3D pulse sequence providing angiographic information in 24 s was tested in five healthy subjects and used prospectively in 21 patients for the investigation of the cervical arteries. Indications included suspected stenosis of the carotid (in 13), or vertebral arteries (in 1), carotid dissection (3), variants of the branches of the aortic arch (2) and extracranial carotid aneurysms (2). The results in all patients were compared with those of intra-arterial digital subtraction angiography (DSA). In patients with carotid stenosis, they were also compared with high-resolution 3D time-of-flight (TOF) MR angiography (MRA). Good quality MR angiograms of the neck vessels were obtained with the fast 3D sequence in 20 of the 21 patients. One claustrophobic patient was unable to cooperate. The degree of internal carotid artery (ICA) stenosis was graded correctly (compared to DSA) in 21 of 24 cases (87.5%). Two mild stenoses were overestimated as moderate using the fast MR sequence and one high-grade stenosis was misdiagnosed as a complete occlusion. Carotid dissection was confirmed in one case and correctly excluded in two. Four extracranial ICA aneurysms in two patients, arterial variants and stenosis of the origin of the vertebral artery were correctly diagnosed using the contrast-enhanced MR angiogram. Three-dimensional TOF MRA was unsuccessful due to motion artefacts in half of the cases of ICA stenosis.
We thank Dr Luiz Celso Hygino Cruz Jr for his interest in our review article 1 on spinal cord MR spectroscopy, and we appreciate the presentation of his own spinal cord MR spectroscopy data acquired from a patient with a non-Hodgkin lymphoma. It is a good example of the feasibility and usefulness of MR spectroscopy in the spinal cord and demonstrates that additional information, which is complementary to other imaging methods, can be obtained. The presentation of these findings could help other clinical groups during the differentiation process in similar cases and may stimulate interest in using spinal cord MR spectroscopy in clinical routine. We also agree that the acquisition protocol can be simplified in comparison with our suggestions in the cited review article 1 in this specific case. However, the simplification of the acquisition protocol is not generally applicable but was enabled by the specific conditions in a case of a space-occupying lesion filling the spinal canal as reported by Dr Hygino da Cruz. The presented lesion is significantly larger compared with the normal diameter of a healthy or even atrophic spinal cord, thus a larger voxel size can be used. In Dr Cruz's article, the voxel size was 2 mL compared with approximately 1.2 mL in healthy spinal cord, 2 which implies an SNR increase by a factor of approximately 1.7. To achieve the same SNR in a smaller spinal cord MR spectroscopy voxel from a healthy or atrophic spinal cord, an increase of at least a factor of 2.9 in scanning time is necessary. In addition, the space-occupying lesion hinders the CSF flow and thus reduces the need for flow-and motion-correction methods. The application at 1.5T in conjunction with a larger lesion also reduces susceptibility changes and thus lowers the requirements for B0 shimming methodology. Compared with 3T, measurements at 1.5T theoretically have a lower SNR. In practice, the SNR difference between 1.5T and 3T is not substantial, 3 due to a better B0 homogeneity at 1.5T leading to a smaller absolute line width along with a more accurate flip angle calibration in the presence of a more homogeneous transmit B1 field and negligible chemical shift displacement artifacts at 1.5T.Furthermore, some lesions show a dramatic increase of specific metabolite concentrations (eg, the presented case seems to exhibit an elevated Cho peak), which can be easily observed with a reduced SNR (unfortunately, the SNR value of the measurement was not reported). The particular situation (a space-occupying lesion versus a normal-diameter spinal cord) minimizes the technical challenges of MR spectroscopy and makes the simplified spinal cord MR spectroscopy protocol used by Dr Cruz and coworkers applicable to the reported case.In conclusion, in some cases, especially when the voxel size can be increased (eg, in space-occupying lesions), a reduction of the scanning time is possible. However, a simplified and shortened MR spectroscopy protocol applied to measurements in other spinal cord conditions might lead to bad spectral quality and ...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.