An 81‐year‐old man with chronic pancreatitis was being treated with a protease inhibitor. He developed an acute exacerbation of chronic pancreatitis and dyspnea. Contrast‐enhanced computed tomography showed disruption of the main pancreatic duct, a cystic lesion connecting the mediastinum to the main pancreatic duct, and left pleural effusion. We diagnosed a pancreatic pseudocyst, mediastinal pancreatic pseudocyst, and pancreatic pleural effusion. Endoscopic retrograde pancreatography showed leakage of contrast medium from the pancreatic body; furthermore, a cystic cavity extending to the mediastinum through a pancreatic duct fistula was visualized. An endoscopic transpapillary nasopancreatic drainage tube was placed in the cystic cavity. Computed tomography showed that the mediastinal pseudocyst and pleural effusion had disappeared. Endoscopic transpapillary pancreatic duct drainage may be useful when a connection between the main pancreatic duct and a mediastinal pseudocyst is confirmed by imaging.
Background Endoscopic ultrasound-guided fine-needle aspiration/biopsy (EUS-FNA/B) is a standard method for pathological diagnosis of pancreatic solid lesions. The EchoTip ProCore 20G® (PC20), a 20-gauge biopsy needle with a forward-bevel core trap, has been available in Japan since 2015. Methods We compared the efficacy of the PC20 with that of the EchoTip ProCore 22G® (PC22) and Acquire 22G® (AC22) in EUS-FNA/B for diagnosing pancreatic cancer. This retrospective study included 191 patients with pancreatic cancer who underwent EUS-FNA/B using the PC20, PC22, or AC22 at our facility from April 2013 to October 2019. We investigated the patients’ clinical characteristics and the diagnostic accuracy and safety of each needle. Results A sufficient stroke length of puncture was secured in all patients. The maximum length under EUS was shorter with the AC22 (22.1 ± 2.2 mm) than PC20 (30.6 ± 0.7 mm, p < 0.01) and PC22 (30.3 ± 0.8 mm, p < 0.01). The histological accuracy was 96.4% with the PC20 but only 58.8% with the PC22 (adjusted p (p-adj) < 0.0001) and 75.0% with the AC22 (p-adj = 0.06). The diagnostic accuracy of the combination of histology and cytology was 96.4% with the PC20, while it was 72.1% with the PC22 (p-adj < 0.0001) and 91.7% with the AC22 (p-adj > 0.99). One patient (0.9%) in the PC20 group developed mild pancreatitis, but no adverse events occurred with the other needles. Conclusions The PC20 showed better diagnostic capability than the PC22. The diagnostic efficacy was similar between the PC20 and AC22. The high histological accuracy of the PC20 could be advantageous for lesions in which histological assessment is critical.
A woman in her 30s who was 12 weeks pregnant with her third child presented with jaundice. Blood tests showed elevated hepatobiliary enzymes and direct bilirubin. Abdominal ultrasonography showed dilatation of the common bile duct and strong echo with a 9 mm acoustic shadow in the distal bile duct. She was diagnosed with common bile duct stone disease and biliary drainage was considered necessary. Percutaneous transhepatic biliary drainage (PTBD) was performed considering the effect on both the fetus and the mother, and the procedure was successful without any complications. The PTBD tube was left in place until delivery at 36 weeks 6 days of gestation and endoscopic stone removal was performed 14 days after delivery. The patient was discharged 18 days after delivery without any complications. In pregnant women with common bile duct stones, palliative PTBD followed by elective endoscopic stone removal after delivery can be considered a treatment strategy.
Background: Endoscopic ultrasound-guided fine-needle aspiration/biopsy (EUS-FNA/B) is a standard method for pathological diagnosis of pancreatic solid lesions. The EchoTip ProCore 20G® (PC20), a 20-gauge biopsy needle with a forward-bevel core trap, has been available in Japan since 2015.Methods: We compared the efficacy of the PC20 with that of the EchoTip ProCore 22G® (PC22) and Acquire 22G® (AC22) in EUS-FNA/B for diagnosing pancreatic cancer. This retrospective study included 191 patients with pancreatic cancer who underwent EUS-FNA/B using the PC20, PC22, or AC22 at our facility from April 2013 to October 2019. We investigated the patients’ clinical characteristics and the diagnostic accuracy and safety of each needle.Results: A sufficient stroke length of puncture was secured in all patients. The maximum length under EUS was shorter with the AC22 (22.1±2.2 mm) than PC20 (30.6±0.7 mm, p<0.01) and PC22 (30.3±0.8 mm, p<0.01). The histological accuracy was 96.4% with the PC20 but only 58.8% with the PC22 (adjusted p (p-adj)<0.0001) and 75.0% with the AC22 (p-adj=0.06). The diagnostic accuracy of the combination of histology and cytology was 96.4% with the PC20, while it was 72.1% with the PC22 (p-adj<0.0001) and 91.7% with the AC22 (p-adj>0.99). One patient (0.9%) in the PC20 group developed mild pancreatitis, but no adverse events occurred with the other needles. Conclusions: The PC20 showed better diagnostic capability than the PC22. The diagnostic efficacy was similar between the PC20 and AC22. The high histological accuracy of the PC20 could be advantageous for lesions in which histological assessment is critical.
Background: Endoscopic ultrasound-guided fine-needle aspiration/biopsy (EUS-FNA/B) is a standard method for pathological diagnosis of pancreatic solid lesions. The EchoTip ProCore 20G® (PC20), a 20-gauge biopsy needle with a forward-bevel core trap, has been available in Japan since 2015.Methods: We compared the efficacy of the PC20 with that of the EchoTip ProCore 22G® (PC22) and Acquire 22G® (AC22) in EUS-FNA/B for diagnosing pancreatic cancer. This retrospective study included 191 patients with pancreatic cancer who underwent EUS-FNA/B using the PC20, PC22, or AC22 at our facility from April 2013 to October 2019. We investigated the patients’ clinical characteristics and the diagnostic accuracy and safety of each needle.Results: A sufficient stroke length of puncture was secured in all patients. The maximum length under EUS was shorter with the AC22 (22.1±2.2 mm) than PC20 (30.6±0.7 mm, p<0.01) and PC22 (30.3±0.8 mm, p<0.01). The histological accuracy was 96.4% with the PC20 but only 58.8% with the PC22 (adjusted p (p-adj)<0.0001) and 75.0% with the AC22 (p-adj=0.06). The diagnostic accuracy of the combination of histology and cytology was 96.4% with the PC20, while it was 72.1% with the PC22 (p-adj<0.0001) and 91.7% with the AC22 (p-adj>0.99). One patient (0.9%) in the PC20 group developed mild pancreatitis, but no adverse events occurred with the other needles. Conclusions: The PC20 showed better diagnostic capability than the PC22. The diagnostic efficacy was similar between the PC20 and AC22. The high histological accuracy of the PC20 could be advantageous for lesions in which histological assessment is critical.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.