A multi-objective identification method for structural model updating based on modal residuals is presented. The method results in multiple Pareto optimal structural models that are consistent with the experimentally measured modal data and the modal residuals used to measure the discrepancies between the measured and model predicted modal
Acromioclavicular joint (ACJ) cyst is an uncommonly documented condition of the shoulder, first described by Craig. 5 According to Hiller's classification, 13 there are 2 types of cysts, based on the various etiologies that generate them. Type I cysts are caused by degenerative changes of the ACJ due to injury, metabolic/infectious disease, or excessive use and are therefore restricted to the joint, with an intact rotator cuff. Gradually, these changes can inflame the synovium, leading to the overproduction of fluid and cyst formation superficial to the ACJ. Type II cysts are associated with rotator cuff tears, partial or complete, and subsequent cuff tear arthropathy, including superior migration of the humeral head and irritation of the inferior ACJ capsule. Synovial fluid from the glenohumeral joint (GHJ) escapes through the subacromial/subdeltoid bursa (Geyser sign) into the ACJ, with the deteriorated capsule acting like a 1-way valve that prevents the fluid from returning, leading to the formation of a cyst. 6 We report a massive cyst over the right ACJ in an 80-yearold man, followed by a short literature review. PubMed database search was carried out using the terms acromioclavicular joint cyst, acromioclavicular joint ganglion cyst, ACJ cyst, and ACJ ganglion cyst. No date criteria were placed. All articles reporting the cyst's size and its underlying pathology, as well as the applied treatment methods and the recurrence rate, were included. The inclusion criteria were (1) full-text studies and (2) English language or official English translation provided. The initial research query provided 166 records. Eleven were excluded as duplicates, and 79 were irrelevant by reviewing the title. In addition, 2 cases describing a juxtaarticular myxoma and chondromyxoid fibroma, respectively, were excluded. From the remaining 76 reports, 10 were rejected by reviewing their abstracts, because of apparent irrelevancy. We tried to retrieve the full text of the remaining 66 articles. For 10 of them, the whole text could not be obtained; therefore, they were excluded. No official English translation was provided for 8 articles, which were also not included. A total number of 48 cases were thoroughly reviewed. Six were rejected because of irrelevant data and 6 because of a low level of evidence. A total of 34 studies finally entered the review, reporting 57 cases of ACJ cysts (Table I). A right-handed 80-year-old man was admitted to the hospital with a mass located above his right ACJ. His medical history was free, with the exception of pulmonary echinococcosis, diagnosed 40 years ago. The patient, a retired manual laborer, denied any previous shoulder trauma or any prior surgeries on the affected side, but complained of chronic right shoulder discomfort and mild pain during daily life activities, because of a gradually increasing shoulder lump. On physical examination, the mass measured 6.5 cm in diameter, 8 cm in length, 5 cm in Institutional review board approval was not required for this case report. This patient provid...
A multi-objective identification method for model updating based on modal residuals is proposed. The method results in multiple Pareto optimal structural models that are consistent with the measured modal data, the class of models used to represent the structure and the modal residuals used to judge the closeness between the measured and model predicted modal data. The conventional single-objective weighted modal residuals method for model updating is also used to obtain Pareto optimal structural models by varying the values of the weights. Theoretical and computational issues related to the solution of the multi-objective and single optimization problems are addressed. The model updating methods are compared and their effectiveness is demonstrated using experimental results obtained from a three-story laboratory structure tested at a reference and a mass modified configuration. The variability of the Pareto optimal models and their associated response prediction variability are explored using two structural model classes, a simple 3-DOF model class and a higher fidelity 546-DOF finite element model class. It is shown that the Pareto optimal structural models and the corresponding response predictions may vary considerably. The variability of Pareto optimal structural model is affected by the size of modelling and measurement errors. This variability reduces as the fidelity of the selected model classes increases.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.