The use of chimney grafts is feasible in the renal and superior mesenteric arteries, as well as in the supra-aortic branches, to facilitate stent-graft repair of thoracic or abdominal aortic lesions with inadequate fixation zones.
SummaryBackgroundStents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy.MethodsThe International Carotid Stenting Study (ICSS) is a multicentre, international, randomised controlled trial with blinded adjudication of outcomes. Patients with recently symptomatic carotid artery stenosis were randomly assigned in a 1:1 ratio to receive carotid artery stenting or carotid endarterectomy. Randomisation was by telephone call or fax to a central computerised service and was stratified by centre with minimisation for sex, age, contralateral occlusion, and side of the randomised artery. Patients and investigators were not masked to treatment assignment. Patients were followed up by independent clinicians not directly involved in delivering the randomised treatment. The primary outcome measure of the trial is the 3-year rate of fatal or disabling stroke in any territory, which has not been analysed yet. The main outcome measure for the interim safety analysis was the 120-day rate of stroke, death, or procedural myocardial infarction. Analysis was by intention to treat (ITT). This study is registered, number ISRCTN25337470.FindingsThe trial enrolled 1713 patients (stenting group, n=855; endarterectomy group, n=858). Two patients in the stenting group and one in the endarterectomy group withdrew immediately after randomisation, and were not included in the ITT analysis. Between randomisation and 120 days, there were 34 (Kaplan-Meier estimate 4·0%) events of disabling stroke or death in the stenting group compared with 27 (3·2%) events in the endarterectomy group (hazard ratio [HR] 1·28, 95% CI 0·77–2·11). The incidence of stroke, death, or procedural myocardial infarction was 8·5% in the stenting group compared with 5·2% in the endarterectomy group (72 vs 44 events; HR 1·69, 1·16–2·45, p=0·006). Risks of any stroke (65 vs 35 events; HR 1·92, 1·27–2·89) and all-cause death (19 vs seven events; HR 2·76, 1·16–6·56) were higher in the stenting group than in the endarterectomy group. Three procedural myocardial infarctions were recorded in the stenting group, all of which were fatal, compared with four, all non-fatal, in the endarterectomy group. There was one event of cranial nerve palsy in the stenting group compared with 45 in the endarterectomy group. There were also fewer haematomas of any severity in the stenting group than in the endarterectomy group (31 vs 50 events; p=0·0197).InterpretationCompletion of long-term follow-up is needed to establish the efficacy of carotid artery stenting compared with endarterectomy. In the meantime, carotid endarterectomy should remain the treatment of choice for patients suitable for surgery.FundingMedical Research Council, the Stroke Association, Sanofi-Synthélabo, European Union.
Purpose: To relate changing abdominal aortic aneurysm (AAA) morphology after endovascular grafting to the presence of leakage, collateral perfusion, and other factors. Methods: Thirty-five patients who underwent successful AAA endovascular grafting were evaluated. Self-expanding Z-stents and Dacron grafts were applied in bifurcated and aortomonoiliac systems. Postoperative diameter changes were calculated from repeated spiral computed tomographic scans, angiograms, and ultrasonic phase-locked echo-tracking scans during a median 6-month follow-up (interquartile range [IQR] 3 to 12). Results: At 12 months, the diameters of completely excluded aneurysms had decreased 6 mm (IQR 2 to 11; p = 0.006). The proximal graft-anchoring stents had dilated 2 mm (IQR 0.5 to 3.3; p = 0.01). The aortic diameters immediately below the renal arteries but above the stents had not changed. Endoleakage and collateral perfusion (n = 13) were each associated with preserved aneurysm size and a 12 times higher risk of aneurysm dilation. After the leakage or the collateral perfusion had been treated, the aneurysm size decreased. Aneurysms with extensive intraluminal thrombi presented a reduced risk of leakage or perfusion. Conclusions: The diameters of endovascularly excluded AAAs decrease, except in cases of leakage or perfusion. Careful follow-up of patients with aortic endografts is necessary.
The size and PWM of aneurysms are reduced after endovascular repair. The diameter reduction may cease after 1.5 years. Endoleaks are associated with higher PWM than expected. Pressure may be transmitted without evidence of leaks.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.