With the cost of energy rising, the value of conservation grows. Interest in energy efficiency could be a sound investment or a necessary public policy. Heat pump systems provide economical alternatives of recovering heat from different sources for use in various applications. The objective of this study is to present the strategic approach on the energy efficient analysis of the water heating system retrofitted by applying a heat pump system in the dormitory of a university. Energy savings were determined by comparing field measurements of water consumption, water temperature and power consumption of the overall system before (electric resistance heating system) and after (heat pump heating system) the implementation of this project. Furthermore, the building energy simulation code (eQuest) has been applied to verify and predict the long-term energy consumption for both water heating systems. The results from energy modelling revealed the good agreement for energy simulation and field measurement data and the improvement of energy efficiency and energy savings could be achieved satisfactorily by retrofitting of a heat pump system. The energy conversion efficiency of hot water for energy consumption at 0.63 (Mcal/Mcal) could be achieved after the application of heat pump water heating system. It also presented the annual saving about USD 20,000 (NTD 600,000) for the dorm by using a heat pump heating system under the electrical billing rate of Taiwan.
Heat pump or usually known as pump energy is a device that can cooling and heating to be used, which functions as a cooling evaporator can be direct replace to heating as a function of the condenser using a reversing valve.. Using heat exchangers in the heat pump system is installed on the suction line and discharge line, so it will give the suction line temperature changes will be higher and discharge line temperatures will be lower, resulting in a greater cooling effect and lighter work of compression. The heat pump uses refrigerant type of hydrocarbon that is friendly to the environment, such as refrigerant R-290. From the results obtained research that the highest of Coefficient of Performance (COP) in the heat pump using heat exchangers is 4.8 and without using heat exchanger is 4.1. So value of COP of haet pump between using heat exchanger and withaout heat exchanger is 0.7. The highest efficiency obtained on the heat pump using heat exchangers is 90.3%, and efficiency of heat pump without using heat exchanger is 78.95%.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.