Background:Patient-specific design (PSD) total knee arthroplasty implants are marketed to restore neutral mechanical-axis alignment (MAA) and provide better anatomic fit compared with standard off-the-shelf (OTS) total knee arthroplasty designs. The purpose was to compare the Knee Society scores, radiographic outcomes, and complications of PSD and OTS implants.Methods:Retrospective study analyzing PSD and OTS by a single surgeon. Implant design change in PSD occurred during the period of data collection leading to PSD-1 and PSD-2 subgroups. Radiographic data including MAA, femorotibial angle, coronal-tibial angle, tibial slope and patella-sulcus angle, and complications were analyzed. Minimum follow-up was 2 years or until revision, and patients completed Knee Society scores preoperatively and postoperatively at 3, 6, 12, 24 weeks, and final follow-up.Results:There were 136 patients (154 knees), average age (62.76 +/− 8.4 years), and follow-up (3.1 +/− 1.5 years). The groups included PSD-1 (77 knees), PSD-2 (36 knees), and OTS (41 knees). The PSD-2 group had better Knee Society function scores compared with PSD-1 and OTS at all timepoints except final follow-up. PSD-2 had significantly shorter hospital stay (P = 0.000012) and less hemoglobin drop (P = 0.032) compared with PSD-1 and OTS. No differences were observed in MAA (P = 0.349) or final range of motion (P = 0.629) between the 3 groups. PSD-2 had more normal femorotibial angle, coronal-tibial angle, and tibial slope compared with PSD-1 and OTS. Failures requiring revision were 23% (18/77) PSD-1, 0% PSD-2, and 3% (1/35) OTS. Most common modes of failure were tibial subsidence (56%) and polyethylene locking mechanism failure (22%) in PSD-1.Conclusion:Catastrophic failure was seen in the PSD-1 group with tibial subsidence and polyethylene locking mechanism failure. PSD-2 had better early Knee Society function scores, shorter hospital stay, lower hemoglobin drop, radiographic alignment, and no failures compared with PSD-1 and OTS.
Aims Infection complicating primary total knee arthroplasty (TKA) is a common reason for revision surgery, hospital readmission, patient morbidity, and mortality. Increasing incidence of methicillin-resistant Staphylococcus aureus (MRSA) is a particular concern. The use of vancomycin as prophylactic agent alone or in combination with cephalosporin has not demonstrated lower periprosthetic joint infection (PJI) rates, partly due to timing and dosing of intravenous (IV) vancomycin administration, which have proven important factors in effectiveness. This is a retrospective review of a consecutive series of primary TKAs examining incidence of PJI, adverse reactions, and complications using IV versus intraosseous (IO) vancomycin at 30-day, 90-day, and one-year follow-up. Methods A retrospective review of 1,060 patients who underwent TKA between May 2016 to July 2020 was performed. There were 572 patients in the IV group and 488 in the IO group, with minimal 30 days of follow-up. Patients were followed up at regularly scheduled intervals (two, six, and 12 weeks). No differences between groups for age, sex, BMI, or baseline comorbidities existed. The IV group received an IV dose of 15 mg/kg vancomycin given over an hour preceding skin incision. The IO group received a 500 mg dose of vancomycin mixed in 150 ml of normal saline, injected into proximal tibia after tourniquet inflation, before skin incision. All patients received an additional dose of first generation cephalosporin. Evaluation included preoperative and postoperative serum creatinine values, tourniquet time, and adverse reactions attributable to vancomycin. Results Incidence of PJI with minimum 90-day follow-up was 1.4% (eight knees) in the IV group and 0.22% (one knee) in IO group (p = 0.047). This preliminary report demonstrated an reduction in the incidence of infection in TKA using IO vancomycin combined with a first-generation cephalosporin. While the study suffers from limitations of a retrospective, multi-surgeon investigation, early findings are encouraging. Conclusion IO delivery of vancomycin after tourniquet inflation is a safe and effective alternative to IV administration, eliminating the logistical challenges of timely dosing. Cite this article: Bone Joint J 2021;103-B(6 Supple A):13–17.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.