Data from longitudinal analyses can be useful in the design and implementation of control strategies.
WHO recommendations for dengue diagnosis require laboratory facilities. Antibody-based rapid diagnostic tests (RDTs) have performed poorly, and clinical diagnosis remains the mainstay in dengue-endemic countries. We evaluated a combination antigen-antibody RDT for point-of-care testing in a high-prevalence setting. In this prospective cohort study, adults were enrolled from a tertiary infectious disease centre for evaluation of undifferentiated febrile illness from October 2011 to May 2012. SD Bioline Dengue Duo was evaluated at point-of-care against a WHO-based reference standard of viral isolation, RT-PCR, NS1-, IgM-, and IgG-ELISA. 246 adults were enrolled (median age 34 years, range 18–69), of which 197 could be confirmed definitively as either dengue or non-dengue. DENV-2 was the predominant serotype (79.5%) and the ratio of primary to secondary cases was 1∶1.1. There were no test failures and minimal interobserver variation with a Fleiss’ kappa of 0.983 (95% CI 0.827–1.00). Overall sensitivity and specificity were 93.9% (95% CI 88.8–96.8%) and 92.0% (95% CI 81.2–96.9%) respectively. Using WHO clinical criteria alone for diagnosis had similar sensitivities (95.9%, 95% CI 91.4–98.1%) and lower specificities (20.0%, 95% CI 11.2–33.0%). No significant difference in performance was found when testing early versus late presenters, primary versus secondary cases, or DENV-1 versus DENV-2 infections. The use of a combination RDT fulfills WHO ASSURED criteria for point-of-care testing and can enhance dengue diagnosis in an endemic setting. This has the potential to markedly improve clinical management of dengue in the field.
Early and accurate diagnosis of dengue is imperative for disease surveillance, which helps in the control of dengue in endemic countries. In this study, we evaluated the performance of three commercially available dengue nonstructural 1 (NS1) antigen assays (Bio-Rad PlateliaÔ Dengue NS1 Antigen ELISA, PanBio Dengue Early ELISA, and Bio-Rad Dengue NS1 Antigen Strip test) and compared them with reverse-transcription polymerase chain reaction (RT-PCR) and other commercially available serological assays for the diagnosis of dengue. The analysis showed RT-PCR to be the most sensitive and specific (100%) diagnostic method during the first 3 days of fever. The overall sensitivity of dengue NS1 antigen assays within the same period was 81.7%, indicating their potential role as a cost-effective and convenient alternative method to RT-PCR for the diagnosis of dengue fever in a primary healthcare setting. However, reduced sensitivity in detecting secondary dengue infections was one of the drawbacks of dengue NS1 antigen assays. Nonetheless, it remains a useful assay for the early detection of dengue and hence could play an important role in routine surveillance efforts to control dengue outbreaks in Singapore.
BackgroundThe sensitivity and specificity of two in-house MAC-ELISA assays were tested and compared with the performance of commercially-available CTK lateral flow rapid test and EUROIMMUN IFA assays for the detection of anti-Chikungunya virus (CHIKV) IgM. Each MAC-ELISA assay used a whole virus-based antigen derived from genetically distinct CHIKV strains involved in two chikungunya disease outbreaks in Singapore (2008); a January outbreak strain with alanine at amino acid residue 226 of the E1 glycoprotein (CHIKV-A226) and a May-to-September outbreak strain that possessed valine at the same residue (CHIKV-226V). We report differences in IgM detection efficacy of different assays between the two outbreaks. The sensitivities of two PCR protocols were also tested.Methods and FindingsFor sera from January outbreak, the average detection threshold of CTK lateral flow test, MAC-ELISAs and EUROIMMUN IFA assays was 3.75, 4.38 and 4.88 days post fever onset respectively. In contrast, IgM detection using CTK lateral flow test was delayed to more than 7 days after fever onset in the second outbreak sera. However, MAC-ELISA using CHIKV-226V detected IgM in the second outbreak sera 3.96 days after fever onset, which was approximately one day earlier compared to the same assay using CHIKV-A226 (4.86 days). Specificity was 100% for both commercial assays, and 95.6% for the in-house MAC-ELISAs. For sensitivity determination of the PCR protocols, the probe-based real time RT-PCR method was found to be 10 times more sensitive than one based on SYBR Green.ConclusionOur findings suggested that the two strains of CHIKV using variants A226 and 226V resulted in variation in sensitivities of the assays evaluated. We postulated that the observed difference in antigen efficacy could be due to the amino acid substitution differences in viral E1 and E2 envelope proteins, especially the E1-A226V substitution. This evaluation demonstrates the importance of appraisal of different diagnostic assays before their application in clinical and operational settings.
Although Singapore has an intensive dengue control program, dengue remains endemic with regular outbreaks. We report development and use of a novel adult oviposition trap, the Gravitrap, in managing dengue cluster areas. The Gravitrap is a simple, hay infusion-filled cylindrical trap with a sticky inner surface to serve as an oviposition site for gravid female Aedes mosquitoes. Wire gauze fitted above the water level minimizes the risk of it being an unwanted breeding habitat. The Gravitrap was deployed in 11 dengue cluster areas throughout Singapore. Aedes aegypti was the predominant mosquito caught in the trap and some (5.73%) were found to be positive for dengue virus.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.