BackgroundImprovements in data processing, increased understanding of the biomechanical background behind kinetics and kinematics, and technological advancements in inertial measurement unit (IMU) sensors have enabled high precision in the measurement of joint angles and acceleration on human subjects. This has resulted in new devices that reportedly measure joint angles, arm speed, and stresses to the pitching arms of baseball players. This study seeks to validate one such sensor, the MotusBASEBALL unit, with a marker-based motion capture laboratory.HypothesisWe hypothesize that the joint angle measurements (“arm slot” and “shoulder rotation”) of the MotusBASEBALL device will hold a statistically significant level of reliability and accuracy, but that the “arm speed” and “stress” metrics will not be accurate due to limitations in IMU technology.MethodsA total of 10 healthy subjects threw five to seven fastballs followed by five to seven breaking pitches (slider or curveball) in the motion capture lab. Subjects wore retroreflective markers and the MotusBASEBALL sensor simultaneously.ResultsIt was found that the arm slot (R = 0.975, P < 0.001), shoulder rotation (R = 0.749, P < 0.001), and stress (R = 0.667, P = 0.001 when compared to elbow torque; R = 0.653, P = 0.002 when compared to shoulder torque) measurements were all significantly correlated with the results from the motion capture lab. Arm speed showed significant correlations to shoulder internal rotation speed (R = 0.668, P = 0.001) and shoulder velocity magnitude (R = 0.659, P = 0.002). For the entire sample, arm slot and shoulder rotation measurements were on a similar scale, or within 5–15% in absolute value, of magnitude to measurements from the motion capture test, averaging eight degrees less (12.9% relative differences) and nine degrees (5.4%) less, respectively. Arm speed had a much larger difference, averaging 3,745 deg/s (80.2%) lower than shoulder internal rotation velocity, and 3,891 deg/s (80.8%) less than the shoulder velocity magnitude. The stress metric was found to be 41 Newton meter (Nm; 38.7%) less when compared to elbow torque, and 42 Nm (39.3%) less when compared to shoulder torque. Despite the differences in magnitude, the correlations were extremely strong, indicating that the MotusBASEBALL sensor had high reliability for casual use.ConclusionThis study attempts to validate the use of the MotusBASEBALL for future studies that look at the arm slot, shoulder rotation, arm speed, and stress measurements from the MotusBASEBALL sensor. Excepting elbow extension velocity, all metrics from the MotusBASEBALL unit showed significant correlations to their corresponding metrics from motion capture and while some magnitudes differ substantially and therefore fall short in validity, the link between the metrics is strong enough to indicate reliable casual use. Further research should be done to further investigate the validity and reliability of the arm speed metric.
BackgroundWeighted-baseball training programs are used at the high school, collegiate, and professional levels of baseball. The purpose of this study was to evaluate the effects of a six-week training period consisting of weighted implements, manual therapy, weightlifting, and other modalities on shoulder external rotation, elbow valgus stress, pitching velocity, and kinematics.HypothesisA six-week training program that includes weighted implements will increase pitching velocity along with concomitant increases in arm angular velocities, joint kinetics, and shoulder external rotation.MethodsSeventeen collegiate and professional baseball pitchers (age range 18–23, average: 19.9 ± 1.3) training at Driveline Baseball were evaluated via a combination of an eight-camera motion-capture system, range-of-motion measurements and radar- and pitch-tracking equipment, both before and after a six-week training period. Each participant received individualized training programs, with significant overlap in training methods for all athletes. Twenty-eight biomechanical parameters were computed for each bullpen trial, four arm range-of-motion measurements were taken, and pitching velocities were recorded before and after the training period. Pre- and post-training period data were compared via post-hoc paired t tests.ResultsThere was no change in pitching velocity across the seventeen subjects. Four biomechanical parameters for the holistic group were significantly changed after the training period: internal rotational velocity was higher (from 4,527 ± 470 to 4,759 ± 542 degrees/second), shoulder abduction was lower at ball release (96 ± 7.6 to 93 ± 5.4°), the shoulder was less externally rotated at ball release (95 ± 15 to 86 ± 18°) and shoulder adduction torque was higher (from 103 ± 39 to 138 ± 53 N-m). Among the arm range of motion measurements, four were significantly different after the training period: the shoulder internal rotation range of motion and total range of motion for both the dominant and non-dominant arm. When the group was divided into those who gained pitching velocity and those who did not, neither group showed a significant increase in shoulder external rotation, or elbow valgus stress.ConclusionsFollowing a six-week weighted implement program, pitchers did not show a significant change in velocity, joint kinetics, or shoulder external rotation range of motion. When comparing pitchers who gained velocity versus pitchers who did not, no statistically significant changes were seen in joint kinetics and shoulder range of motion.
We describe a generic approach to image interpretation, based on combining a general method of building flexible template models with genetic algorithm (GA) search. The method can be applied to a given image interpretation problem simply by training a statistical shape model, using a set of examples of the image structure to be located. A local optimization technique has been incorporated into the GA search and shown to improve the speed of convergence and optimality of solution. We present results from three medical applications, demonstrating that the new method offers significant improvements when compared with previously reported approaches to flexible template matching, particularly the ability to deal with different domains of application using a standard method and the possibility of employing complex multipart models. We also describe how the method can be simply extended to track structures in image sequences and segment three dimensional objects in volume images.
Time constraints often result in the challenge to fit desired programming into training time allotments. Wearable resistance (WR) may be an option to optimise the training content in function of constrained training time. The purpose of this study was to determine the effects of a lower-limb WR sprint running training intervention on athlete speed capabilities following a nine-week off-season, low volume training period within a sample of American football high school athletes. Nineteen athletes completed pre- and post-intervention testing of two maximal effort 30 m sprints. Horizontal force-velocity mechanical profiling variables, sprint times, and maximal velocity were calculated from sprint running velocity data collected by a radar device. The athletes completed seventeen dedicated sprint training sessions during the off-season. The intervention (WR) group completed the sessions with 1% body mass load attached to the shanks (i.e. 0.50% body mass load on each limb). The control group completed the same training sessions unloaded. Post-intervention, no statistically significant between group differences were observed ( p > 0.05). However, athletes in both groups experienced increases in velocity measures following the sprint training. The greater adjusted mean theoretical maximal velocity scores ( p > 0.05; ES = 0.30) found for the WR group compared to the control group at post-intervention may suggest that WR amplifies the nuances of the training protocol itself. Coaches can consider using lower-limb WR training to increase in-session workloads during periods of low volume training but more research is needed to better understand to what extent WR training might provide an added value to optimise both the training content and planning, as well as the athlete’s training response in order to improve sprint running performance.
Long-term training effects of weighted ball throwing programs have been well documented. However, the mechanisms by which these effects are facilitated are poorly understood due to the difficulty of measuring biomechanics in the baseball throwing motion. The purpose of this study is to replicate previous methods investigating within-session effects of throwing overload and underload baseballs to provide mechanistic evidence for weighted baseball training methods. We hypothesized that varying the pitched ball weight between three, four, five, six, and seven ounces will affect pitched ball velocity, upper body kinematics, lower body kinematics, kinematic velocities, and throwing arm joint kinetics during a maximum intent throwing workout. Twenty-six collegiate and professional level baseball pitchers ages 20-30 (mean age 23.5 ± 2.7 years) participated in a pitch velocity and biomechanical evaluation while pitching a series of leather weighted baseballs from a regulation pitching mound. A one-way repeated measures ANOVA was used to evaluate the within-subject effect of ball weight on a total of 15 parameters: pitch velocity, five kinematic positions, four kinematic velocities, and five kinetics. We found that as ball weight increased, pitch velocity, maximum elbow flexion, maximum pelvis rotation velocity, maximum shoulder internal rotation velocity, and maximum elbow extension velocity decreased, while anterior trunk tilt at ball release increased. Training with three- to seven-ounce baseballs can be used to work on increasing pitching velocity without increasing throwing arm joint kinetics or changing pitching mechanics in a practically significant way.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.