The procedures resulted in highly reliable MFCV values, and included: (1) electric identification of motor points prior to electrode placement; (2) twitch identification of muscle fiber orientation to guide initial electrode placement; (3) rotation of electrodes clockwise or counter-clockwise to maximize the similarity and delay of compound muscle action potentials across all detection surfaces; and (4) minimization of synergistic activity during voluntary contractions.
Motor unit discharge rates determined during a brief, submaximal contraction were decreased in the potentiated human tibialis anterior muscle.
ObjectiveRecent research has reported that lower maximal rate of torque development (dτ/dt max) exhibited by females, relative to males, during knee extension can be accounted for by normalization to a maximal voluntary contraction (MVC); however, this was not seen in the upper limb.PurposeThe aim of the current work was to examine the contribution of maximum strength (τmax), twitch contraction time (CT), muscle fiber condition velocity (MFCV), and rate of muscle activation (Q30) to sex-differences in the dτ/dt max during maximal isometric dorsiflexion.MethodsThirty-eight participants (20 males; 18 females) performed both maximal voluntary and evoked isometric contractions of the tibialis anterior across 3 days. Ten maximal compound muscle action potentials were elicited and subsequently followed by three, 5-s contractions. From the recordings, MFCV, dτ/dt max, τmax, CT, electromechanical delay (EMD), root-mean squared (RMS) amplitude, peak-to-peak voltage (Vpp), and Q30 were calculated.ResultsAn ANCOVA showed that τmax accounted for all the sex-differences in dτ/dt max (p = 0.96). There were no significant differences between groups with respect to MFCV, RMS amplitude, Vpp amplitude, or CT. However, there was a significant sex-difference in dτ/dt max, τmax, and Q30. Females had longer evoked EMD times compared with males (15.69 ± 10.57 ms versus 9.95 ± 3.46 ms; p = 0.01), but the voluntary EMD times were not different.ConclusionThe current research supports the work by Hannah et al. Exp Physiol 97:618–629, (2012) that normalization to MVC in the quadriceps is able to account for all sex-differences in rate of toque development in the lower limb.
The time delay between two surface electromyograms (EMGs) acquired along the conduction path is used to estimate mean action potential conduction velocity. Modeling the linear impulse response between "upstream" and "downstream" EMG signals permits an estimate of the distribution of velocities, providing more information. In this work, we analyzed EMG from bipolar electrodes placed on the tibialis anterior of 36 subjects, using an inter-electrode distance of 10 mm. Regularized least squares was used to fit the coefficients of a finite impulse response model. We trained the model on one recording, then tested on two others. The optimum correlation between the model-predicted and actual EMG averaged 0.70. We also compared estimation of the mean conduction delay from the peak time of the impulse response to the "gold standard" peak time of the cross-correlation between the upstream and downstream EMG signals. Optimal models differed from the gold standard by 0.02 ms, on average. Model performance was influenced by the regularization parameters. The impulse responses, however, incorrectly contained substantive power at very low time delays, causing delay distribution estimates to exhibit high probabilities at very short conduction delays. Unrealistic distribution estimates resulted. Larger inter-electrode spacing may be required to alleviate this limitation.
Mean electromyogram (EMG) conduction delay is often estimated as the average time delay between two surface EMG recordings arranged along the conduction path. It has previously been shown that the complete distribution of conduction delays can be estimated from the impulse response relating the "upstream" EMG recording to the "downstream" recording. In this work, we examined regularized least squares methods for estimating the impulse response, namely the pseudo-inverse with small singular values discarded and post hoc lowpass filtering. Performance was evaluated by training the model to one recording, then testing on others. Correlation between model-predicted EMG and measured EMG was assessed for 36 subjects, using EMG recordings with 5 mm inter-electrode spacing. The best correlation was 0.86, on average, for both regularization methods. We additionally compared the mean conduction delay computed from the "gold standard" cross-correlation method to the peak time of the impulse response. The best models differed by 0.01 ms, on average, for both regularization methods. Nonetheless, the impulse responses exhibited excessive energy near zero time, causing delay distribution estimates to exhibit high probabilities at unphysiological short time delays. Inter-electrode spacing larger than 5 mm may be required to alleviate this limitation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.