Objectives To evaluate the analytical and clinical performance of the automated Elecsys anti–severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibody (Elecsys Ab) assay on the Roche cobas e602 analyzer. With the ongoing global coronavirus disease 2019 (COVID-19) pandemic, widespread and routine serologic testing of SARS-CoV-2 remains a pressing need. To better understand its epidemiologic spread and to support policies aimed at curtailing further infections, reliable serologic testing is crucial for providing insight into the dynamics of the spread of COVID-19 on a population level. Methods The presence of anti–SARS-CoV-2 antibodies in polymerase chain reaction–positive, confirmed COVID-19 patient samples was determined using the Elecsys Ab assay on the Roche cobas e602 analyzer. The precision and cross-reactivity of the Elecsys Ab assay were characterized and its performance was compared against the EuroImmun IgA/IgG antibody (EuroImmun Ab) assay. Calculated sensitivity, specificity, and positive and negative predictive values were assessed. Results The Elecsys Ab assay demonstrated good precision, had no cross-reactivity with other viral samples, and showed 100% concordance with the EuroImmun Ab assay. Excellent clinical performance with respect to sensitivity, specificity, and positive and negative predictive values was observed. Conclusions The Elecsys Ab assay is a precise and highly reliable automated platform for clinical detection of seropositivity in SARS-CoV-2 infection.
The evaluation of surgically resected papillary thyroid carcinomas (PTC) by immunohistochemistry (IHC) for BRAF mutation has diagnostic, prognostic and therapeutic implications. The goal of this meta-analysis was to perform a systematic review of studies using the VE1 clone (specific for detection of the BRAF V600E mutation) on formalin-fixed paraffin embedded (FFPE) thyroid surgical resection specimens for primary papillary thyroid carcinoma. The authors' molecular techniques, immunohistochemistry protocols, and scoring methods for VE1 immunostaining were also evaluated. This study included 4079 PTCs representing data from 23 studies. The results extracted from each study were split into two different groups, direct sequencing group or PCR group, based on the molecular "gold standard" method used to compare VE1 IHC staining. In the direct sequencing group, the IHC sensitivity was 100% (95% CI 0.97-1.00) and specificity 84% (95% 0.72-0.91). In the PCR group the sensitivity was 98% (95% CI 0.96-0.99) and specificity 89% (95% CI 0.82-0.94). Although immunohistochemical procedures varied by author, the overall performance of the VE1 clone shows that it is highly sensitive and relatively specific for detecting the BRAF V600E mutation in surgical resection specimens. However, standardization of immunohistochemical procedural method and scoring/interpretation criteria may improve the reliability and reproducibility for the use of VE1 clone for future practice.
Objectives To evaluate the analytical and clinical performance of the Truvian Easy Check coronavirus disease 2019 (COVID-19) IgM/IgG anti-severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibody test. Serologic assays have become increasingly available for surveillance through the Food and Drug Administration emergency use authorization in the ongoing COVID-19 global pandemic. However, widespread application of serologic assays has been curbed by reports of faulty or inaccurate tests. Therefore, rapid COVID-19 antibody tests need to be thoroughly validated prior to their implementation. Methods The Easy Check device was analytically evaluated and its performance was compared with the Roche Elecsys anti-SARS-CoV-2 antibody assay. The test was further characterized for cross-reactivity using sera obtained from patients infected by other viruses. Clinical performance was analyzed with polymerase chain reaction-confirmed samples and a 2015 prepandemic reference sample set. Results The Easy Check device showed excellent analytical performance and compares well with the Roche Elecsys antibody assay, with an overall concordance of 98.6%. Clinical performance showed a sensitivity of 96.6%, a specificity of 98.2%, and an overall accuracy of 98.1%. Conclusions The Easy Check device is a simple, reliable, and rapid test for detection of SARS-CoV-2 seropositivity, and its performance compares favorably against the automated Roche Elecsys antibody assay.
High containment biological laboratories (HCBL) are required for work on Risk Group 3 and 4 agents across the spectrum of basic, applied, and translational research. These laboratories include biosafety level (BSL)-3, BSL-4, animal BSL (ABSL)-3, BSL-3-Ag (agriculture livestock), and ABSL-4 laboratories. While SARS-CoV-2 is classified as a Risk Group 3 biological agent, routine diagnostic can be handled at BSL-2. Scenarios involving virus culture, potential exposure to aerosols, divergent high transmissible variants, and zoonosis from laboratory animals require higher BSL-3 measures. Establishing HCBLs especially those at BSL-4 is costly and needs continual investments of resources and funding to sustain labor, equipment, infrastructure, certifications, and operational needs. There are now over 50 BSL-4 laboratories and numerous BSL-3 laboratories worldwide. Besides technical and funding challenges, there are biosecurity and dual-use risks, and local community issues to contend with in order to sustain operations. Here, we describe case histories for distinct HCBLs: representative national centers for diagnostic and reference, nonprofit organizations. Case histories describe capabilities and assess activities during COVID-19 and include capacities, gaps, successes, and summary of lessons learned for future practice.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.