Objectives: To investigate the biomechanical properties of a lateral locked plate alone or in combination with a supplemental medial plate or an intramedullary nail (IMN). Methods: Intra-articular distal femur fractures with metaphyseal comminution (OTA/AO 33-C) were simulated with a standardized model in 28 synthetic femora and divided into 4 groups. Group I was instrumented with a 4.5-mm lateral locked distal femoral plate alone, group II with a lateral locked plate plus a low-profile precontoured 3.5-mm medial distal tibial plate, group III with a lateral locked plate plus a medial 3.5-mm reconstruction plate, and group IV with a lateral locked plate plus a retrograde IMN. Specimens were then axially loaded and cycled to failure or runout. Outcomes of interest were baseline stiffness, survivability, and cycles to failure. Results: Groups III and IV have a significantly higher baseline stiffness (P < 0.001) when compared with groups I and II. Furthermore, groups III and IV had a higher max load to failure (P < 0.01) when compared with groups I and II. The survivability in groups III and IV was 71% and 100%, respectively, while no specimens in group I or II survived maximum loading. There was no significant difference between group III and IV regarding stiffness, survivability, and cycles to failure. Conclusion: When considering fixation for intra-articular distal femur fractures with metaphyseal comminution (OTA/AO 33-C), we found that supplementation of a lateral locked plate with a medial plate or an IMN to be biomechanically superior to lateral locked plating alone regarding stiffness, survivability, and cycles to failure. A low-profile precontoured plate did not add significantly to the construct stiffness in this study.
Surgeons may use blocking screws to aid in fracture alignment during retrograde nail fixation. In addition, the placement of long segment blocking screws can help resist failure of fixation in geriatric patients by eliminating the "Bell-clapper effect."
Polymethyl methacrylate (PMMA) is commonly used in orthopedic surgery and has several applications, most often for fixation of arthroplasty components. While its overall safety and tolerance are well described, less is known regarding the thermal properties of PMMA as it sets from a liquid to solid state, as well as the potential for osseous thermal necrosis. This study addresses potential variations in the setting time and maximum temperature of PMMA formulations in common use and explores the potential clinical implications of this variability. Seven commercially available formulations of PMMA that varied by brand and/or viscosity were obtained and prepared according to manufacturer's instructions. Peak temperature and duration were measured in controlled settings for each type and compared to previously described thresholds for thermal bone necrosis. Depuy SmartSet (HV), Zimmer Palacos R (HV), and Zimmer Palacos (LV) exceeded the 56°C threshold reported to potentially induce immediate osseous thermal necrosis. Additionally, Biomet Cobalt (MV) and Stryker Simplex P (MV) had lower peak temperatures but exceeded thermal necrosis thresholds due to curing duration. The lowest peak temperature was observed for Smith & Nephew Versabond (MV), which was significantly lower than all types except Depuy SmartSet (MV). Setting time was not significantly different among groups. There are significant differences in the thermal properties of PMMA formulations in current use. Selection of specific PMMA formulations represents an additional route of procedural optimization depending on the needs of the treating surgeon.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.