Tension pneumothorax during ventilating bronchoscopy for foreign body removal is a rare but life-threatening complication. The authors present a case of cardiac arrest caused by tension pneumothorax in a 9-month-old girl who underwent ventilating bronchoscopy for foreign body (peanut) removal. Tension pneumothorax was due to tracheobronchial lacerations caused by a bronchoscope. The patient was successfully resuscitated by cardiopulmonary resuscitation and chest tube insertion. The airway injury was effectively repaired by thoracotomy under extracorporeal membrane oxygenation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.