M-doped zinc oxide (ZnO) (M 5 Al and/or Ni) thermoelectric materials were fully densified at a temperature lower than 10001C using a spark plasma sintering technique and their microstructural evolution and thermoelectric characteristics were investigated. The addition of Al 2 O 3 reduced the surface evaporation of pure ZnO and suppressed grain growth by the formation of a secondary phase. The addition of NiO promoted the formation of a solid solution with the ZnO crystal structure and caused severe grain growth. The co-addition of Al 2 O 3 and NiO produced a homogeneous microstructure with a good grain boundary distribution. The microstructural characteristics induced by the co-addition of Al 2 O 3 and NiO have a major role in increasing the electrical conductivity and decreasing the thermal conductivity, resulting from an increase in carrier concentration and the phonon scattering effect, respectively, and therefore improving the thermoelectric properties. The ZnO specimen, which was sintered at 10001C with the co-addition of Al 2 O 3 and NiO, exhibited a ZT value of 0.6 Â 10 À3 K À1 , electrical conductivity of 1.7 Â 10 À4 X À1 . m À1 , the thermal conductivity of 5.16 W . (m . K) À1 , and Seebeck coefficient of À425.4 lV/K at 9001C. The ZT value obtained respects the 30% increase compared with the previously reported value, 0.4 Â 10 À3 K À1 , in the literature. J ournal
BackgroundThe relatively recently developed I-gel (Intersurgical Ltd., Workingham, England) is a supraglottic airway device designed for single-use that, unlike conventional LMAs, does not require an inflatable cuff. In addition, the I-gel, much like the Proseal LMA (PLMA), has a gastric drainage tube associated with an upper tube for decompression of the stomach, thereby avoiding acid reflux and decreasing the risk of pulmonary absorption. The purpose of this study was to compare PLMA and I-gel devices in patients undergoing gynecological laparoscopy based on sealing pressure before and during pneumoperitoneum, insertion time, and gas exchange.MethodsFollowing Institutional Review Board approval and written informed consent, 30 adult patients were randomly allocated to one of two groups (the PLMA or I-gel group). In each case, insertion time and number of attempts were recorded. After successful insertion, airway leak pressure was measured.ResultsSuccessful insertion and mechanical ventilation with both supraglottic airway devices was achieved on the first attempt in all 30 patients, and there were no significant differences with respect to insertion time. Likewise, leak pressure did not vary significantly either between or within groups after CO2 insufflation. In addition, differences between leak volume and leak fraction between groups were not significant.ConclusionsThe results of our study indicate that the I-gel is a reasonable alternative to the PLMA for controlled ventilation during laparoscopic gynecologic surgery.
BackgroundThe greater occipital nerve (GON) block has been frequently used for different types of headache, but performed with rough estimates of anatomic landmarks. Our study presents the values of the anatomic parameters and estimates the effectiveness of the ultrasound-guided GON blockade.MethodsThe GON was detected using ultrasound technique and distance from external occipital protuberance (EOP) to GON, from GON to occipital artery and depth from skin to GON was measured in volunteers. Patients with occipital headache were divided into two groups (ultrasound-guided block: group S, conventional blind block: group B) and GON block was performed. The same parameters were measured on group S and VAS scores were assessed at pretreatment, 1 week and 4 weeks after treatment on both groups.ResultsThe GON had distance of 23.1 ± 3.4 mm (right) and 20.5 ± 2.8 mm (left) from EOP to GON. Its depth below the skin was 6.8 ± 1.5 mm (right) and 7.0 ± 1.3 mm (left). The distance from GON to occipital artery was 1.5 ± 0.6 mm (right) and 1.2 ± 0.6 mm (left) in volunteers. Initial VAS score of group S and group B patients were 6.4 ± 0.2 and 6.5 ± 0.2. VAS score of 4 weeks after injection were 2.3 ± 0.2 on group S and 3.8 ± 0.3 on group B (P = 0.0003).ConclusionsThe parameters measured in this study should be useful for GON block and ultrasound-guided blockade is likely to be a more effective technique than blind blockade in occipital headache treatment.
BackgroundAlthough acute tolerance to opioids, especially to remifentanil, has been demonstrated consistently in animal studies, the results of clinical trials in humans are controversial. The aim of this study was to determine whether intraoperative infusions of remifentanil used as an adjuvant in general anesthesia result in acute tolerance, an event manifested by increased postoperative pain and a higher opioid requirement than usual.MethodsSixty patients who underwent surgery under general anesthesia for spinal fusion were randomly assigned to receive sevoflurane-nitrous oxide-oxygen (group SO, n = 20), sevoflurane-remifentanil-nitrous oxide-oxygen (group SR, n = 20), or propofol-remifentanil-oxygen (group PR, n = 20) in a double-blinded manner. All patients within 1 hour after induction received PCA (fentanyl 0.4 µg/kg/ml and ondansetron 16 mg) administered intravenously at a basal infusion rate of 1 ml/h, after being intravenously injected with a loading dose of fentanyl (1 µg/kg). Data for fentanyl requirement, verbal Numerical Rating Scale (NRS) pain score at rest, and presence of nausea or vomiting were collected at 1, 24, and 48 hours after surgery.ResultsWe did not find any significant difference in postoperative PCA fentanyl requirements, NRS or side effects among the groups.ConclusionsRemifentanil as an adjuvant to sevoflurane or propofol in general anesthesia for adults having surgery for spinal fusion does not appear to cause acute opioid tolerance or hyperalgesia in patients. However, further studies are needed to elucidate whether sevoflurane and propofol exert a clinically significant effect on opioid-induced tolerance or hyperalgesia and whether this effect is related to the age of the patient, the dose and duration of remifentanil given and the intensity of pain experienced postoperatively.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.