Background: The use of a functionally closed system for the glycerolization and deglycerolization of red blood cells (RBCs) allows for prolonged post-thaw storage for more than 24 hours. The aim of this study was to assess glycerolization and deglycerolization processing for RBCs using a high glycerol method in the automated, closed system provided by Haemonetics ACP 215. Methods: Thirty-five packed RBCs were glycerolized using the ACP 215 to a final concentration of 40% (wt/vol). The units were either frozen as such (n=30) or excess glycerol was removed (n=5) before freezing. After storage at-80 o C, the units were thawed, deglycerolized and resuspended in SAG-M. The frozen-thawed RBCs were stored at 4 o C, and analyzed for their stability and in vitro quality. Results: No prefreeze excess glycerol removal units showed significantly less potassium leakage during post-thaw storage compared to the prefreeze excess glycerol removal units. All measurements of the stability and in vitro quality of thawed RBCs prepared from frozen RBCs without the prefreeze removal of excess glycerol during post-thaw storage at 4 o C for 7 days were acceptable to the American Blood Bank Association's standards and European standards. Conclusion: RBCs frozen without prefreeze removal of excess glycerol and the ACP 215 simplifies cryopreservation procedure and increases the stability of frozen-thawed RBCs. This increases the practical applicability of cryopreserved RBCs in blood transfusion practice.
Background: In the Korean Red Cross, anti-HTLV (Human T-cell lymphotropic virus)-1/2 screening assay has been performed in all donated blood except plasmapheresis since April 2009. For anti-HTLV-1/2 positive donors, both Western blot (WB) and nucleic acid amplification test (NAT) are performed as confirmatory assays. In this study, we evalutated the efficiency of the current confirmatory assay scheme to improve the confirmatory assay scheme for anti-HTLV1/2. Methods: The results of the HTLV confirmatory assay from April 15th 2009 to April 14th 2015 were analyzed using the Blood Information Management System of the Korean Red Cross. We also investigated the current situation in other countries. Results: Of 12,923,854 donations, 3,483 (0.027%) showed positive results in anti-HTLV-1/2. Of the 3,483 donations, 499 (14.3%) showed positive results in WB or NAT or both. The number of positive cases in both was 461. Therefore, the concordance rate was 92.4%. In the cases of positive results only in NAT, the WB results were all indeterminate (ID). Most countries are using immunoblot assay as a confirmatory assay for anti-HTLV positive blood donors. In the results, there were no cases of positive result in only NAT with a negative result in immunoblot assay. Conclusion: It was considered that the accomplishment of only WB as a confirmatory assay for anti-HTLV-1/2 positive donors may be sufficient in the aspect of safety and economics. However, in the case of WB ID result, it may be better to perform NAT as a supplemental test.
The blood supply can become disrupted in situations of increased demand during unexpected national catastrophes and when a patient needs a rare blood transfusion, which depends on the blood inventory in peacetime. Cryopreservation of blood, which can be stored up to 10 years, represents a possible solution to this problem by avoiding storage lesions. This review describes frozen red cell technologies, quality control issues related to post-thaw red blood cells, and preconditions and practical considerations for implementation of a frozen blood banking system in Korea.
HLA-matched platelet transfusion is required for patients with platelet refractoriness due to HLA alloimmunity. From 2013 to 2019, the Korean Red Cross has recruited 4,080 donors for HLA-matched platelets. The patient's HLA information should be submitted to the Korean Red Cross in accordance with the WHO HLA serologic specificities. When HLA-matched platelets are requested, the Korean Red Cross selects the appropriate donors based on Duquesnoy's matching grade classification (1977) and CREGs defined by Takemoto, Fuller, and Rodey ( 2007) and then contacts them to request blood donations. Platelets of HLA-matched donors are collected by apheresis and supplied to the hospital. To make this process more efficient, the Korean Red Cross introduced a systemic standard work procedure using a computer program for blood donor management and HLA matching. Owing to the extensive polymorphism of the HLA types, expansion of the donor pool would be required to supply HLA-matched platelets sufficiently. As the number of registered donors for HLA-matched platelets is limited, it should only be ordered when the indication criteria for its use are met. The Korean Red Cross is planning to study genotype-based matching strategies for patients with rare HLA types and receive patients' laboratory test results from medical institutions to evaluate the effectiveness of HLA-matched platelet transfusions.
Background: Since 2001, the Korean Red Cross has performed malaria antibody test for blood donors in malaria-risk areas to prevent transfusion-transmitted malaria. However, due to insufficient sensitivity and specificity the malaria antibody assay is not considered an efficient screening method. Therefore, we have considered discontinuing malaria antibody testing for blood donors. Methods: We analyzed the results of malaria antibody test from 2001 to 2014 utilizing data from the Blood Information Management System of the Korean Red Cross. Results: Among 16,650,812 donations tested from 2001 to 2014, 50,143 donations (0.30%) showed positive results. However, there was no truly infected case at the time of donation. The positive rate among blood donations was between 34 and 39 per 10,000 in 2001, but between 9 and 10 per 10,000 in 2014. There was no interregional disparity in the positive rate of blood donations. Conclusion: Korea is in a malaria elimination phase and malaria antibody testing in limited areas is not effective, therefore we propose discontinuing the malaria antibody test.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.