In this study, the bottom cabinet of a commercial household refrigerator is investigated numerically. The numerical model is formed in two stages. The first stage includes the fan motion, and the second stage includes the heat rejection process at the condenser. The compressor is included in the numerical model to get the accurate simulation of the real conditions. A protective lid covering the condenser and the fan is taken into consideration for both stages of the numerical solution. In the numerical analysis, the total amount of heat transfer, temperature, pressure and velocity gradients and streamlines are studied in detail. Due to the location and the design of the fan, a static fluid region occurs at the mid-section of the condenser. Therefore, the number of wires on the mid-section of the condenser tubes and the cost can be decreased. It is observed that the compressor is also cooled by the discharged air from the condenser.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.