On behalf of the European Society of Contact DermatitisPatch testing is the predominant method of establishing contact allergy. The present patch test technique is the result of a continuous process of development and improvement since its first application in the late 19th century. The perfect patch test should give no false-positive and no false-negative reactions. The ideal patch test should also cause as few adverse reactions as possible, particularly no patch test sensitization. Even though the history and examination of a patient with suspected allergic contact dermatitis will give clues to possible sensitizers, it is not sufficient to patch test only with initially suspected sensitizers; unsuspected sensitizers used for patch testing frequently turn out to be the real cause of the dermatitis. Fortunately, a small number of substances are considered to account for the majority of delayed hypersensitivity reactions. Therefore, generally 20-25 test preparations consisting of chemically defined compounds, mixes of allergens, and natural and synthetic compounds, are grouped into a standard test series. The requirements to be fulfilled by a sensitizer in a standard patch test series are discussed in this article. A procedure of investigations is proposed before a sensitizer is included in a standard series.
230 patients with occupational dermatitis in the metallurgic industry were studied with standard patch test (GEIDC) and an oil series. An occupational and clinical questionnaire survey was carried out. Responses to paraphenylenediamine, chrome, cobalt in the standard series, and benzisothiazolone, triethanolamine, and Grotan BK were the main positive results.
We report the patch test results of 449 construction workers who came as patients to the Occupational Dermatology Service of the Instituto Nacional de Medicina y Seguridad del Trabajo in Madrid between 1989 and 1993. 90.8% of them were patch tested, because they had cutaneous lesions or a clinical history suggestive of occupational dermatitis. 65.5% (268) of those patch tested showed one or more reactions connected with their work. Chromate at 42.1% was the main allergen, followed by cobalt, 20.5%, nickel, 10%, and epoxy resin, 7.5%. 25.9% (106) of patients showed sensitization to rubber components, the majority at 23.7% to thiuram mix, with TETD being the main allergen.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.