Postpartum haemorrhage (PPH) is caused by obstetric complications but may be exacerbated by haemostatic impairment. In a 10-year programme of research we have established that haemostatic impairment is uncommon in moderate PPH and that fibrinogen falls earlier than other coagulation factors. Laboratory Clauss fibrinogen and the point-of-care surrogate measure of fibrinogen (FIBTEM A5 measured on the ROTEM Ò machine) are predictive biomarkers for progression from early to severe PPH, the need for blood transfusion and invasive procedures to control haemorrhage. Fibrinogen replacement is not required in PPH unless the plasma level falls below 2 g/L or the FIBTEM A5 is below 12 mm. Deficiencies of coagulation factors other than fibrinogen are uncommon even during severe PPH, and ROTEM Ò monitoring can inform withholding FFP safely in most women. In the absence of placental abruption, clinically significant thrombocytopenia is uncommon unless the platelet count is low before the bleed started, or very large bleeds (>5000 mL) occur. Measuring blood loss is feasible in routine practice during PPH and is more accurate than estimation. These research findings have been collated to design an ongoing quality improvement programme for all maternity units in Wales called OBS Cymru (Wales) (The Obstetric Bleeding Strategy for Wales).
SummaryWe compared the classic laryngeal mask airway and i-gel as adjuncts to fibrescope guided intubation in a manikin. Two methods of intubation were compared with each device: the tracheal tube directly over the fibrescope; and the tracheal tube over an Aintree Intubation Catheter. Thirty-two anaesthetists took part in this randomised crossover study. Each anaesthetist performed two intubations with each method via each device. The mean (SD) time for the first intubation using the tracheal tube over the fibrescope was 43 (24) s with the classic laryngeal mask airway and 22 (9) s with the i-gel (95% CI for the difference 12-30 s, p < 0.0001). The mean (SD) times for the first intubation when using the Aintree Intubation Catheter was 46 (24) s with the classic laryngeal mask airway and 37 (9) s with the i-gel (95% CI for the difference 5-12 s, p < 0.0001). We recorded five (5 ⁄ 64, 8%) oesophageal intubations when using the classic laryngeal mask airway and none when using the i-gel. The participants rated the ease of railroading of the tracheal tube and railroading the Aintree Intubation Catheter over the fibrescope to be significantly easier (p < 0.0001 and p = 0.002 respectively) when using the i-gel than when using the classic laryngeal mask airway. Furthermore, 30 ⁄ 32 (94%) of anaesthetists reported preference for the i-gel over the classic laryngeal mask airway for fibrescope guided tracheal intubation when managing a difficult airway. We conclude that the i-gel is likely to be a more appropriate conduit than the classic laryngeal mask airway for fibrescope guided intubation irrespective of the intubation method used.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.