Purpose: To evaluate LithoVue, the new single-use digital flexible ureteroscope, in a human cadaveric model and compare it with a nondisposable fiber optic and digital flexible ureteroscopes.Materials and Methods: LithoVue, a conventional fiber optic, and digital flexible ureteroscopes were each tested in four renal units of recently deceased female cadavers by three surgeons. The following parameters were analyzed: accessibility to the kidney and navigation of the entire collecting system with and without ureteral access sheath (UAS), lower pole access measuring the deflection of the ureteroscope with the working channel empty, and with inside two different baskets and laser fibers. A subjective evaluation of maneuverability and visibility was assessed by each surgeon at the end of every procedure.Results: Kidney access into the Renal unit 1 was not possible without UAS for all ureteroscopes because of noncompliant ureter at the level of sacroiliac joint. The reusable digital ureteroscope was unable to reach one calix of the lower pole and one calix of the upper pole (Renal units 2 and 3) without UAS placement. Lower pole access with baskets and laser fibers was possible for each ureteroscope after UAS placement. No statistically significant differences were detected in angle deflection between ureteroscopes. The digital ureteroscope was preferred for visibility in all procedures: LithoVue for maneuverability in six procedures, fiber optic in five procedures, and the digital ureteroscope in one procedure.Conclusions: LithoVue seems to be comparable with conventional ureteroscopes in terms of visibility and manipulation into the collecting system in fresh human cadavers. Further studies in humans are needed to determine the clinical value of this new instrument.
Laser use during flexible ureteroscopy may cause increased intrarenal temperatures. Rapid increases should be kept in mind when irrigation is closed. The irrigation seems to limit the temperature increase when used with any laser setting.
Kidney stone disease (KSD) is a complex disease. Besides the high risk of recurrence, its association with systemic disorders contributes to the burden of disease. Sufficient water intake is crucial for prevention of KSD, however, the mineral content of water might influence stone formation, bone health and cardiovascular (CVD) risk. This study aims to analyse the variations in mineral content of bottled drinking water worldwide to evaluate the differences and describes the possible impact on nephrological and urological diseases. The information regarding mineral composition (mg/L) on calcium, bicarbonate, magnesium, sodium and sulphates was read from the ingredients label on water bottles by visiting the supermarket or consulting the online shop. The bottled waters in two main supermarkets in 21 countries were included. The evaluation shows that on a global level the mineral composition of bottled drinkable water varies enormously. Median bicarbonate levels varied by factors of 12.6 and 57.3 for still and sparkling water, respectively. Median calcium levels varied by factors of 18.7 and 7.4 for still and sparkling water, respectively. As the mineral content of bottled drinking water varies enormously worldwide and mineral intake through water might influence stone formation, bone health and CVD risk, urologists and nephrologists should counsel their patients on an individual level regarding water intake.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.