The construction, operation and demolition of buildings represent one of the most damaging human activities in the global environment nowadays and water use and conservation is one of the most representative environmental loads to be considered. Brazil, unlike some other countries, has not yet implemented its own body building environmental assessment. The development of an environmental assessment system requires the identification of the most important topics to be considered in each theme for each country or region, due to local environmental agenda. This article presents a summary of the main topics concerning water conservation considered in some international environmental building assessment systems and presents a proposal of topics to take into account in a Brazilian assessment system. Practical application: The civil construction industry is not only one of the biggest sectors in the economy but is also one of the greatest polluters. Along with standardisation, it is also necessary to establish measures to attract significantly higher levels in different topics related to sustainable construction. New mechanisms that allow users to recognise the difference between buildings with different sustainable performance levels need to be developed. This article will be used as a base for the development of a Brazilian system of assessment and rating for building environmental performance and sustainability in terms of water use and conservation.
The objective of this study was to test the hypothesis that high-producing dairy cows become increasingly resistant to insulin throughout lactation and that, consequently, oocyte quality is compromised. We used Holstein cows at 50 (51.5±3.7; n=30), 100 (102.3±9.4; n=30), and 150 (154.5±18.9; n=30) days in milk (DIM). We measured circulating insulin and glucose and performed a glucose tolerance test (GTT) after 5h of fasting. To evaluate oocyte quality, we performed ovum pickup on the day before the GTT (581 oocytes). We performed statistical analyses using the MIXED procedure of SAS. The model included the fixed effects of DIM, period, time, parity, and an interaction between DIM and time. We observed no difference in the GTT between groups for any variable related to circulating glucose (for example, glucose peak=203.3±7.2, 208.8±6.3, and 194.3±5.9mg/dL). However, various measures of circulating insulin were different in cows at 150 DIM compared with 50 or 100 DIM: higher basal insulin (8.8±0.9, 8.8±0.8, and 11.9±0.8 µIU/mL), peak insulin (61.9±6.2 69.1±5.7, and 89.0±6.1 µIU/mL), delta maximum insulin (51.1±5.5 59.4±5.0, and 73.5±5.4 µIU/mL), and area under the curve 5-60 (1,874.8±171.0 2,189.5±157.8, and 2,610.5±174.0 µIU/mL × min). Nevertheless, we observed no difference among groups in the number of viable oocytes (3.2±0.7, 3.9±0.7, and 3.6±0.7 per cow per ovum pickup) or percentage of viable oocytes (49.3, 52.2, and 51.8%). Increased circulating insulin before and throughout the GTT in cows at 150 DIM indicates that cows develop increasing insulin resistance with increasing DIM; however, increased insulin resistance was not associated with a detectable alteration in the quality of oocytes aspirated from small and medium-sized follicles.
This paper presents a method to establish the design flow rate adopting probabilistic and possibilistic approaches to model the subjective behaviour of the users that affects strongly the duration of usage of sanitary appliances. At first, the Monte Carlo method is used to determine the instance of usage of the sanitary appliances. After that, fuzzy logic is applied to determine the duration of the shower. As a result, historical records of the use of the sanitary appliances and the flow rate during the peak period can be generated. The design flow rate obtained by the simulation is about 23% lower than that assessed by the Brazilian standard, based on deterministic approach, and closer to the values calculated by the probabilistic model. Practical application: As the processing cost is extremely low, the simulation based on the proposed method is also an efficient means to obtain a quite accurate estimate of the flow rate for the sizing of water supply systems and water meters in water sub-metering systems.
The aim of this study was to compare plasma progesterone (P4) concentrations in nonlactating, multiparous Holstein cows (n = 24) treated with 2 types of intravaginal implants containing either 1.0 or 1.9 g of P4 either at the first use or during reuse of the implants after sanitizing the implant by autoclave or chemical disinfection. In a completely randomized design with a 2 × 3 factorial arrangement and 2 replicates, every cow underwent 2 of 6 treatments. Two sources of P4 [controlled internal drug release (1.9 g of P4) from Zoetis (São Paulo, Brazil), and Sincrogest (1.0 g of P4) from Ourofino (Cravinhos, Brazil)] and 3 types of processing, new (N), reused after autoclave (RA), and reused after chemical disinfection (RC), were used. After inducing luteolysis to avoid endogenous circulating P4, the cows were randomized in 1 of 6 treatments (1.9 g of N, 1.9 g of RA, 1.9 g of RC, 1.0 g of N, 1.0 g of RA, and 1.0 g RC). Cows were treated with the implants for 8 d and during this period blood samples were collected at 0, 2, 12, 24, 48, 72, 96, 120, 144, 168, and 192 h. Statistical analyses were performed using Proc-Mixed and the mean ± standard error of the mean P4 concentrations were calculated using the Proc-Means procedures of SAS 9.4 (SAS Institute Inc., Cary, NC). No interaction between treatments was observed. Comparing types of implant, average P4 concentrations during treatments were greater for 1.9 g than 1.0 g (1.46 vs. 1.14 ± 0.04 ng/mL). When types of processing were compared, average P4 concentrations did not differ between autoclaved and new inserts (1.46 vs. 1.37 ± 0.05 ng/mL; respectively), but both were greater than chemically disinfected implants (1.09 ± 0.04 ng/mL). Within 1.9-g P4 inserts, P4 concentrations from autoclaved implants were greater than new, which were greater than chemically disinfected (1.67 ± 0.06 vs. 1.49 ± 0.07 vs. 1.21 ± 0.05 ng/mL; respectively). For 1.0-g P4 implants, P4 concentrations from autoclaved did not differ from new, but both were greater than chemically disinfected (1.20 ± 0.08 vs. 1.24 ± 0.06 vs. 0.97 ± 0.05 ng/mL; respectively). In conclusion, the mean plasma P4 concentration in nonlactating Holstein cows was greater for 1.9 than 1.0 g of P4 and regardless of the type of implant, the autoclaving process provided greater circulating P4 in relation to chemical disinfection, and similar or greater P4 concentrations compared with a new implant.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.