In 1984 and 1985, 352 hips were randomly assigned to total hip arthroplasty with either low- or high-viscosity cement at 5 Swedish orthopedic departments. Of the 267 hips finally included in the study, 226 were examined clinically and radiographically after 54-77 months. Radiographically, 21 definite stem loosenings and 1 probable stem loosening were observed (10 percent) and 4 additional stems had been exchanged before the 5-year examination. In the survivorship analysis, 261 stem prostheses were included and using this method, 7 percent were radiographically loose after 5 years. There were 4 definitely loose and 8 probably loose acetabular cups. No difference was found between cement of high and low viscosity with regard to prosthetic fixation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.