This study was performed to compare the frequency of early complications after single chamber versus dual chamber permanent pacemaker implantation. Early complication was defined as one occurring in the 6-week period following implantation. We prospectively analyzed consecutive pacemaker implantation from January 1987 to June 1993 at our regional center. All complications were also analyzed for the relationship to operator experience, the venous access route, and the presence of temporary pacing wire at the time of implantation of the permanent pacing system. A total of 2019 new pacemaker units were implanted during this period. 1733 patients (85.8%) received a VVI pacemaker and 286 (14.2%) a DDD unit. Wound infection occurred in 11 (0.6%) VVI patients and 6 (2.1%) DDD patients. Lead displacement occurred in 18 (1%) VVI patients and 15 (5.2%) DDD patients (11 [3.8%] atrial and 4 [1.4%] ventricular). There were 10 (0.6%) pneumothoraces, 9 (0.5%) hematomas requiring drainage, 1 (0.06%) chylocele, and 2 (0.1%) deaths in the VVI group. There were 2 (0.7%) pneumothoraces, 2 (0.7%) hematomas, and no deaths in the DDD group. There was no significant increase in complications for experienced infrequent implanters (< 12 systems per year). In both groups the subclavian approach was associated with a risk of pneumothorax when compared to the cephalic approach. The rate of wound infection was higher in patients who had a temporary pacing wire in place. The use of prophylactic antibiotics does not appear to affect the incidence of wound infection.(ABSTRACT TRUNCATED AT 250 WORDS)
Objective-To determine the rate of late complications following first implantation or elective unit replacement of a permanent pacemaker system. Design-Analysis of pacemaker data and complications prospectively acquired on a computerised database. Complications were studied over an 11 year period from January 1984 to December 1994. Setting-Tertiary referral cardiothoracic centre. Patients-Records of 2621 patients were analysed retrospectively. Main outcome measures-Complications requiring repeat procedures occurring more than six weeks after pacemaker implantation or elective unit replacement. Results-The overall rate of late complications was significantly lower after first implantation of a permanent pacemaker (34 cases, complication rate 1.4%, 95% confidence interval 0.9% to 1.9%) than after elective unit replacement (16 cases, complication rate 6.5% (3.3% to 9.7%). There were 20 cases of erosion, 18 infections, five electrode problems, and seven miscellaneous problems. Complications were more common with inexperienced operators (18.9% (6.0% to 31.8%)) than with experienced operators (0.9% (0.3% to 1.5%)). Conclusions-The incidence of late complications following pacemaker implantation is low and compares favourably with early complication rates. The majority are caused by erosion and infection. Patients who have undergone elective unit replacement are at particular risk. (Heart 1998;80:240-244)
Patent foramen ovale (PFO) is known to occur with greater prevalence in those with cryptogenic stroke. These observations support the role of a PFO as a channel for paradoxical embolism and a mechanism for cerebral ischaemic events. Transcatheter closure of PFO may be indicated in this setting. A prerequisite of procedural success is achieving complete closure of the shunt. Studies have shown a varying degree of successful shunt closure. Residual shunts are usually the result of a mismatch between the device shape and PFO anatomy. In this article, we review the features of PFO and their surrounding structures as seen by three-dimensional transoesophageal echocardiography in patients undergoing transcatheter closure and relate these to the variations in morphology on anatomical specimens for a better appreciation of their suitability for closure devices. The salient features of the anatomical variations seen in adults undergoing transcatheter device closure have been summarized and used to produce a practical pre-procedural checklist.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.