Folded plates have attracted profound interest in recent years because of their economic advantages and architectural appearance. In particular, their basic structural response is indeed logical enough, explicit and simple although its required numerical computation procedure is, in a little bit, boring. This type of structures have gained increasing popularity and offers more advantages than more complex structures, such as cylindrical shells, arches and right folded plate frames. Similarly, the thin-walled cellular bridge decks can be treated as a multi-folded plates structure. This study produces an overall review of the historical development of the most popular methods utilized for analysis the folded plate structures which are offered with their applications and how these methods are developed gradually. Four common methods are chosen in this paper to show their highlights of references particularizing in analysis of the above mentioned types of structure; the folded plate elasticity method (FPEM), finite element method (FEM), finite strip method (FSM) and spline finite strip method (SFSM). This investigation covers the elastic behavior, and the experimental researches on the elastic reaction of folded plate structures.
Efficient supplementary materials flourish the structural performance and sustainability of reinforced concrete structures. Steel fiber is one of these materials that have significant influence on enhancing tensile and flexural strengths and ductility of high strength reinforced concrete columns. This paper presents a review study on the structural performance of steel fiber reinforced concrete columns. The studied case was related to the columns that subjected to concentric or eccentric compression loads or combined compression loads and cyclic lateral loads. The current survey is divided into two branches; the first is related to fibreless HSC columns, while the other is specialized by SFRHSC ones. In addition to the prime actuator (steel fiber content), the investigated parameters were included concrete strength, transverse reinforcement properties, and axial load ratio. The results of this investigation showed that the positive influence of adding steel fiber on improving the flexural strength, fatigue life and resistance, delaying spalling failure of the exterior concrete shell and outward buckling of the longitudinal steel reinforcing bars. The optimum volume fraction of steel fiber used is 0.5% to 2% (by weight) and when 2% of steel fibers are introduced into the concrete mix, the columns’ cover didn’t spall away.
The composite opened web steel joist supported floor systems have been common for many years. It is economic and has light weight and can embed the electrical conduit, ductwork and piping, eliminating the need for these to pass under the member, consequently eliminate the height between floors. In order to study the joist strength capacity under the various conditions, it had been fabricated seven joists composed of the steel and concrete slab connected to the top chord by shear connectors (headed studs). These joist have 2820 mm length c/c of the supports and 235 mm overall depth. In the present study, six variable parameters are adopted (Studs distribution, Degree of shear connection, Degree of the web inclination, Shape of the web, Density of concrete for slab and length of the shear connector). The test results exhibited that minimum strength capacity was 160kN for light weight joist and maximum capacity was 225kN for joist of long shear connectors at failure. The results were compared by ultimate flexural model by Azmi.
In this study, the analytic model (Azmi Model) had been considered for computation the load capacities of the composite open web steel joists and compared them with those obtained from experimental tests. The capacities of seven joists had been studied, each including one of the following variables (distribution of headed studs, connection degree of the connectors, inclination of the web, shape of the web, density of slab concrete, length of connectors).Theoretically, according to the Analytic model, the referenced joist of (45° web inclination , uniformly distributed ,over connected ,short headed studs) exhibited maximum load capacity of (18.45) ton, while the joist of (45° web inclination, uniformly distributed, under connected, short headed studs) exhibited minimum load capacity of (16.23) ton at yield point of bottom chord. Experimentally, the referenced joist exhibited maximum load capacity of (15.51) ton, while the joist of (34° web inclination, uniformly distributed, over connected, short headed studs) exhibited (12.49) ton load capacity. The load capacities values of the tested joists ranged between (67%-85%) of the predicted values according to the analytic model.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.