The purpose of this study is to find an optimization approach to minimize the absorbed dose to adult patients undergoing CT examination, while maintain the diagnostic image quality. A single detector CT was considered, to represent typical practice in King Hamad University Hospital. We included 626 patients in this study and investigated radiation dose for three anatomical regions, head, chest and abdomen and pelvis. For each type of CT examination, two groups of patients were considered. 383 patients in Group I: were imaged according to the protocols set by the manufacturer. Group II: 243 patients were imaged according to the protocols set by our team after optimization. We were able to adjust the adjustable factors such as noise index, scan time, pitch, rotation time and slice thickness. For each examination the weighted volume CT dose index (CTDIvol) and dose length product (DLP) were recorded and noise is measured. Each study was also reviewed for image quality. Measured (CTDIvol, DLP) were compared to international reference levels. For Group I, the CTDIvol and DLP values were higher than the reference levels. After Dose optimization the CTDIvol and DLP values were significantly reduced to have lower values than the reference levels. The results of our study showed that the CTDIvol and DLP values taken from images done using the protocols set by the Ct machine developers are higher than the reference levels which indicate that manufacturers are focusing their efforts toward improving image quality rather than the minimizing the dose that can be given to the patient.
The incidence of autism spectrum disorders (ASD) has been rising, but the causes of ASD remain largely unidentified. Collective data have implicated the increased human exposure to electromagnetic fields (EMF) in the increasing incidence of ASD. There are established biological effects of extremely low-frequency (ELF) EMF, but the relation to ASD is not investigated enough. In this study we examined the effects of perinatal exposure to ELF EMF on some ASD-relevant behavioral parameters in mice. The EMF was delivered via a Helmholtz coil pair. Male BALB/C mice were used and divided into exposed and control groups (n=8 and n=9, respectively). Tests were used to assess sociability, preference for social novelty, locomotion, anxiety, exploratory behavior, motor coordination, and olfaction. The examined mice were all males and exposed to EMF during the last week of gestation and for 7 days after delivery. The exposed mice demonstrated a lack of normal sociability and preference for social novelty while maintaining normal anxiety-like behavior, locomotion, motor coordination, and olfaction. Exposed mice also demonstrated decreased exploratory activity. We concluded that these results are supportive of the hypothesis of a causal link between exposure to ELF-EMF and ASD; however, replications of the study with further tests are recommended.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.