The incidence of head and orofacial injuries among professional handball players is high. Mouthguards prevented severe dental injuries such as tooth fracture and avulsion, but their use was still limited.
Neither Er:YAG nor Nd:YAG dental lasers exhibited adequate surface modification for bonding of orthodontic brackets on glazed lithium disilicate ceramics compared with the control treated with 9.5% HF.
This study aimed to investigate the effects of radiotherapy on the mechanical, chemical, and surface properties of two recently introduced restorative dental materials (a glass hybrid and an alkasite), while two conventional restorative materials served as references. Material specimens of the experimental groups (irradiated) were compared to the specimens of the control groups that underwent the same preparation procedure but without irradiation. The experimental groups of restorative material specimens were irradiated with a total of 70 Gy over 35 days (2 Gy/day × 35 days), while the control groups received no treatment. The following properties were evaluated: surface microhardness (Vickers), surface roughness, color change, flexural strength, flexural modulus, material reliability, and infrared spectra. For the experimental groups, measurements were performed 24 h after specimen preparation, i.e., before radiotherapy and after the completion of the irradiation protocol. For the control groups, measurements were performed after the corresponding periods of no treatment. A statistically significant increase in microhardness (p = 0.001–0.004) and surface roughness (p = 0.013) was observed as a result of material aging/maturation in both the control and experimental groups. However, the only statistically significant difference between the control and experimental groups was observed in the discoloration of the conventional reference material (p < 0.001). In conclusion, no statistically significant negative effects of a therapeutic dose of radiotherapy on any of the tested properties of the alkasite and glass hybrid materials were observed, whereas only a minor negative effect of radiotherapy in terms of discoloration was found for a conventional resin composite that was used as a reference material.
This case report describes the management of a crown-root fractured maxillary right central incisor and a crown fractured maxillary left central incisor using two different techniques.A complex procedure was designed to manage this case including orthodontic extrusion to move the fracture line above the alveolar bone and surgical recontouring of the altered gingival margin. Finally, the right incisor was restored prosthodontically. Prosthetic treatment was based on performing a post and core, and all-ceramic crown on the extruded tooth. The left, less-damaged incisor was restored directly using composite resin.The treatment resulted in good esthetics and secured periodontal health. This case report demonstrates that a multidisciplinary treatment approach is a reliable and predictable option to save a tooth.How to cite this article: Ortolan SM, Strujic M, Aurer A, Viskic J, Bergman L, Mehulic K. Esthetic Rehabilitation of Complicated Crown Fractures Utilizing Rapid Orthodontic Extrusion and Two Different Restoration Modalities. Int J Clin Pediatr Dent 2012;5(1):64-67.
The data about bond strength between digitally produced denture base resins and artificial teeth are scarce. Several studies investigated shear bond strength values of milled denture base resins and different types of artificial teeth. The purpose of the present study was to compare and evaluate the available evidence through a systematic review. A bibliographic search was conducted in PubMed, Scopus, and Web of Science to assess adequate studies published up to 1 June 2022. This review followed the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. The appropriate studies that determined the shear bond strength values between milled denture base resins and artificial teeth were selected. The initial search identified 103 studies, which were included in the PRISMA 2020 flow diagram for new systematic reviews. Three studies met the inclusion criteria, and all of them present a moderate risk of bias (score 6). Two studies found no statistical differences between heat-polymerized and CAD/CAM (milled) denture base materials when attached with different types of artificial teeth, while one study showed higher values of CAD/CAM (milled) denture base materials. Bonding agents ensure bonding strength at least similar to the conventional methods. In order to improve the quality of future studies, it would be advantageous to use a larger number of specimens with standardized dimensions and a blinded testing machine operator to decrease the risk of bias.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.