Evaporative cooling technology (ECT) has been deemed as an alternative to the conventional vapor-compression air conditioning system for dry climates in recent years due to its simple structure and low operating cost. Generally speaking, the ECT includes two types of different technologies, direct evaporative cooling (DEC) and indirect evaporative cooling (IEC). Both technologies can theoretically reduce the air temperature to the wet-bulb temperature of outdoor air. The major difference between these two technologies is that DEC will introduce extra moisture to the supply air while IEC will not. The enhanced IEC, Maisotsenko-cycle (M-cyle) IEC, can even bring down the air temperature to the dew point temperature. The ECT integrated with solid desiccant systems, i.e., solid desiccant-assisted evaporative cooling technologies (SDECT), could make the technology applicable to a wider range of weather conditions, e.g., weather with high humidity. In this paper, the recent development of various evaporative cooling technologies (ECT), solid desiccant material and the integration of these two technologies, the SDECT, were thoroughly reviewed with respect to their configuration, optimization and desiccant unit improvement. Furthermore, modeling techniques for simulating SDECT with their pros and cons were also reviewed. Potential opportunities and research recommendations were indicated, which include improving the structure and material of M-cycle IEC, developing novel desiccant material and optimizing configuration, water consumption rate and operation strategy of SDECT system. This review paper indicated that the SDECT system could be a potential replacement for the conventional vapor-compressed cooling system and could be applied in hot and humid environments with proper arrangements.
In this paper, the cooling and freshwater generation performance of a novel hybrid configuration of a solid desiccant-based M-cycle cooling system (SDM) combined with a humidification–dehumidification (HDH) desalination unit is analysed and compared in three operational modes: ventilation, recirculation, and half recirculation. The HDH unit in this system recycles the moist waste air sourced from the M-cycle cooler and rotary desiccant wheel of the SDM system to enhance water production. A mathematical model was established and solved using TRNSYS and EES software. The results of this study indicate that the recirculation mode exhibited superior cooling performance compared to the other two modes, producing up to 7.91 kW of cooling load and maintaining a supply air temperature below 20.85 °C and humidity of 12.72 g/kg under various ambient conditions. All the operational modes showed similar water production rates of around 52.74 kg/h, 52.43 kg/h, and 52.14 kg/h for the recirculation, half-recirculation and ventilation modes, respectively, across a range of operating temperatures. The recirculation mode also exhibited a higher COP compared to the other modes, as the environmental temperature and relative humidity were above 35 °C and 50%. However, it should be noted that the implementation of the recirculation mode resulted in a higher water consumption rate, with a maximum value of 5.52 kg/h when the inlet air reached 45 °C, which partially offset the benefits of this mode.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.