Purpose: The aim of this study was to evaluate the safety and efficacy of ultrasound cyclo-plasty (UCP) for reducing intraocular pressure (IOP) in patients with glaucoma. Methods: This is a multicentre prospective study conducted in 3 Italian glaucoma centres. UCP was performed by EyeOP1, which delivers ultrasound beams using 6 piezoelectric transducers activated for 4/6 s (first generation) or 8 s (second generation). Primary outcomes were the mean IOP reduction and the rates of success after 1 year. Secondary outcomes were the mean IOP reduction at each follow-up, and the reduction of the number of hypotensive medications. Results: In total, 49 eyes from 47 patients were treated. One year postoperatively, the mean IOP had decreased from 27.7 ± 9.2 to 19.8 ± 6.9 mm Hg (p < 0.001), and the mean number of hypotensive drops and tablets had decreased from 3.2 and 0.5 to 2.3 and 0.2, respectively (p < 0.05). Postoperative IOP reduction was significantly related to preoperative IOP (r2 = 0.5034; p < 0.0001). Second-generation probes determined a significantly higher IOP reduction (p < 0.05). Qualified success was achieved in 25 eyes (51.1%) and complete success in 21 (42.9%), while failure was recorded in 12 (24.5%). Conclusions: UCP is safe and effective for reducing IOP. The procedure determines a greater IOP reduction in patients with higher preoperative IOP. Second-generation probes improve outcomes without detrimental effects on safety.
PURPOSE.To assess quantitatively the choriocapillaris (CC) perfusion area in the macular area of healthy eyes, eyes with primary open-angle glaucoma, and eyes with ocular hypertension using optical coherence tomography angiography (OCTA). METHODS.A consecutive series of healthy individuals and patients with glaucoma and ocular hypertension were recruited prospectively in this single-center, cross-sectional study based in Milan, Italy. OCTA was performed in the morning and evening, along with a complete ophthalmologic examination. Macular superficial capillary plexus vessel density (SCP-VD) and the thicknesses of the retina and ganglion cell complex (GCC), as well as their fluctuations, were investigated. RESULTS.Thirty-nine eyes from 24 individuals with glaucoma (mean age = 58.79 ± 6 years), 43 eyes from 27 individuals with ocular hypertension (59.19 ± 6 years), and 54 eyes from 35 controls (58.27 ± 6 years) were enrolled. The mean CC perfusion area values were not significantly different among the three groups in the morning or evening (P ≥ 0.47). In contrast, SCP-VD, retinal thickness, and GCC thickness were statistically different among the groups (P ≤ 0.016), except for the foveal SCP-VD (P ≥ 0.19) and the evening foveal thickness (P = 0.57). Diurnal changes in the CC perfusion area, SCP-VD, retinal thickness, and GCC thickness were not statistically significant (P ≥ 0.16). Systemic hypertension, sex, age, axial length, and diurnal changes in intraocular pressure were not significantly associated with morning or evening measurements, or with diurnal fluctuations (P ≥ 0.07). CONCLUSIONS.The macular CC flow perfusion area appears unaffected in eyes with primary open-angle glaucoma. No significant diurnal changes were observed in any of the parameters investigated.
Ultrasound cyclo plasty (UCP) is a recently developed surgical technique for glaucoma allowing a selective and controlled coagulation of the ciliary body. We herein investigated the long-term efficacy and safety of UCP for the treatment of glaucoma. This prospective study included patients with primary and secondary glaucoma. All surgeries were performed using the EyeOP1 device (Eye Tech Care, Rillieux-la-Pape, France). Sixty-six patients were included, and 60 completed regularly the 2-year follow-up. Preoperative IOP was 28.5 ± 9.6 mmHg and significantly decreased to 17.0 ± 5.4 at 2 years (p < 0.001). The daily number of both hypotensive eye drops and acetazolamide tablets decreased significantly (respectively, from 2.6 ± 1.1 to 1.7 ± 1.2 and from 0.7 ± 0.8 to 0.2 ± 0.5; both p < 0.001). At 2 years, 68.1% of patients met the definition of qualified success (IOP < 21 mmHg regardless of glaucoma medications) and 10.3% of patients met the definition of complete success (IOP < 21 mmHg without glaucoma medications). No major intra- or postoperative complications occurred; however, 15 eyes required additional glaucoma surgery. These results suggest that UCP is an effective and safe procedure to reduce IOP in glaucoma patients through a 2-year follow-up period.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.