A critical question facing the field of metabolomics is whether data obtained from different centers can be effectively compared and combined. An important aspect of this is the interlaboratory precision (reproducibility) of the analytical protocols used. We analyzed human samples in six laboratories using different instrumentation but a common protocol (the AbsoluteIDQ p180 kit) for the measurement of 189 metabolites via liquid chromatography (LC) or flow injection analysis (FIA) coupled to tandem mass spectrometry (MS/MS). In spiked quality control (QC) samples 82% of metabolite measurements had an interlaboratory precision of <20%, while 83% of averaged individual laboratory measurements were accurate to within 20%. For 20 typical biological samples (serum and plasma from healthy individuals) the median interlaboratory coefficient of variation (CV) was 7.6%, with 85% of metabolites exhibiting a median interlaboratory CV of <20%. Precision was largely independent of the type of sample (serum or plasma) or the anticoagulant used but was reduced in a sample from a patient with dyslipidaemia. The median interlaboratory accuracy and precision of the assay for standard reference plasma (NIST SRM 1950) were 107% and 6.7%, respectively. Likely sources of irreproducibility were the near limit of detection (LOD) typical abundance of some metabolites and the degree of manual review and optimization of peak integration in the LC-MS/MS data after acquisition. Normalization to a reference material was crucial for the semi-quantitative FIA measurements. This is the first interlaboratory assessment of a widely used, targeted metabolomics assay illustrating the reproducibility of the protocol and how data generated on different instruments could be directly integrated in large-scale epidemiological studies.
ObjectiveThe objective of the present study was to investigate associations between sugar intake and overweight using dietary biomarkers in the Norfolk cohort of the European Prospective Investigation into Cancer and Nutrition (EPIC-Norfolk).DesignProspective cohort study.SettingEPIC-Norfolk in the UK, recruitment between 1993 and 1997.SubjectsMen and women (n 1734) aged 39–77 years. Sucrose intake was assessed using 7 d diet diaries. Baseline spot urine samples were analysed for sucrose by GC-MS. Sucrose concentration adjusted by specific gravity was used as a biomarker for intake. Regression analyses were used to investigate associations between sucrose intake and risk of BMI>25·0 kg/m2 after three years of follow-up.ResultsAfter three years of follow-up, mean BMI was 26·8 kg/m2. Self-reported sucrose intake was significantly positively associated with the biomarker. Associations between the biomarker and BMI were positive (β=0·25; 95 % CI 0·08, 0·43), while they were inverse when using self-reported dietary data (β=−1·40; 95 % CI −1·81, −0·99). The age- and sex-adjusted OR for BMI>25·0 kg/m2 in participants in the fifth v. first quintile was 1·54 (95 % CI 1·12, 2·12; P trend=0·003) when using biomarker and 0·56 (95 % CI 0·40, 0·77; P trend<0·001) with self-reported dietary data.ConclusionsOur results suggest that sucrose measured by objective biomarker but not self-reported sucrose intake is positively associated with BMI. Future studies should consider the use of objective biomarkers of sucrose intake.
At high altitude oxygen delivery to the tissues is impaired leading to oxygen insufficiency (hypoxia). Acclimatisation requires adjustment to tissue metabolism, the details of which remain incompletely understood. Here, metabolic responses to progressive environmental hypoxia were assessed through metabolomic and lipidomic profiling of human plasma taken from 198 human participants before and during an ascent to Everest Base Camp (5,300 m). Aqueous and lipid fractions of plasma were separated and analysed using proton (1H)-nuclear magnetic resonance spectroscopy and direct infusion mass spectrometry, respectively. Bayesian robust hierarchical regression revealed decreasing isoleucine with ascent alongside increasing lactate and decreasing glucose, which may point towards increased glycolytic rate. Changes in the lipid profile with ascent included a decrease in triglycerides (48–50 carbons) associated with de novo lipogenesis, alongside increases in circulating levels of the most abundant free fatty acids (palmitic, linoleic and oleic acids). Together, this may be indicative of fat store mobilisation. This study provides the first broad metabolomic account of progressive exposure to environmental hypobaric hypoxia in healthy humans. Decreased isoleucine is of particular interest as a potential contributor to muscle catabolism observed with exposure to hypoxia at altitude. Substantial changes in lipid metabolism may represent important metabolic responses to sub-acute exposure to environmental hypoxia.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.