Background-Simple conceptual ideas about cardiac resynchronization therapy assume that biventricular (BiV) pacing results in collision of right and left ventricular (LV) pacing-derived wavefronts. However, this concept is contradicted by the minor reduction in QRS duration usually observed. We investigated the electric mechanisms of cardiac resynchronization therapy by performing detailed electric mapping during extensive pacing protocols in dyssynchronous canine hearts. Methods and Results-Studies were performed in anesthetized dogs with acute left bundle-branch block (LBBB, n=10) and chronic LBBB with tachypacing-induced heart failure (LBBB+HF, n=6). Activation times (AT) were measured using LV endocardial contact and noncontact mapping and epicardial contact mapping. BiV pacing reduced QRS duration by 21±10% in LBBB but only by 5±12% in LBBB+HF hearts. Transseptal impulse conduction was significantly slower in LBBB+HF than in LBBB hearts (67±9 versus 44±16 ms, respectively), and in both groups significantly slower than transmural LV conduction (≈30 ms). In both groups QRS duration and vector and the epicardial AT vector amplitude and angle were significantly different between LV and BiV pacing, whereas the endocardial AT vector was similar. During variation of atrioventricular delay while LV pacing, and ventriculo-ventricular delay while BiV pacing, the optimal hemodynamic effect was achieved when epicardial AT and QRS vectors were minimal and endocardial AT vector indicated LV preexcitation.
Conclusions-Due
Background-The relative contribution of electromechanical synchronization and ventricular filling to the optimal hemodynamic effect in cardiac resynchronization therapy (CRT) during adjustment of stimulation-timings is incompletely understood. We investigated whether optimal hemodynamic effect in CRT requires collision of pacing-induced and intrinsic activation waves and optimal filling of the left ventricle (LV). Methods and Results-CRT was performed in dogs with chronic left bundle-branch block (n=8) or atrioventricular (AV) block (n=6) through atrial (A), right ventricular (RV) apex, and LV-basolateral pacing. A 100 randomized combinations of A-LV/A-RV intervals were tested. Total activation time (TAT) was calculated from >100 contact mapping electrodes. Mechanical interventricular dyssynchrony was determined as the time delay between upslopes of LV and RV pressure curves. Settings providing an increase in LVdP/dt max (maximal rate of rise of left ventricular pressure) of ≥90% of the maximum LVdP/dt max value were defined as optimal (CRT opt ). Filling was assessed by changes in LV end-diastolic volume (EDV; conductance catheter technique). In all hearts, CRT opt was observed during multiple settings, providing an average LVdP/dt max increase of ≈15%. In AV-block hearts, CRT opt exclusively depended on interventricular-interval and not on AVinterval. In left bundle-branch block hearts, CRT opt occurred at A-LV intervals that allowed fusion of LV-pacing-derived activation with right bundle-derived activation. In all animals, CRT opt occurred at settings resulting in the largest decrease in TAT and mechanical interventricular dyssynchrony, whereas LV EDV hardly changed. Conclusions-In left bundle-branch block and AV-block hearts, optimal hemodynamic effect of CRT depends on optimal interplay between pacing-induced and intrinsic activation waves and the corresponding mechanical resynchronization rather than filling.
Cardiac resynchronization therapy (CRT) is an important therapy for patients with heart failure and conduction pathology, but the benefits are heterogeneous between patients and approximately a third of patients do not show signs of clinical or echocardiographic response. This calls for a better understanding of the underlying conduction disease and resynchronization. In this review, we discuss to what extent established and novel animal models can help to better understand the pathophysiology of dyssynchrony and the benefits of CRT.Electronic supplementary materialThe online version of this article (doi:10.1007/s12265-011-9336-5) contains supplementary material, which is available to authorized users.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.