The data suggest that playing ice hockey at an elite level during childhood is associated with an increased risk for cam-type deformity and hip pain after physeal closure.
A total knee arthroplasty performed with navigation results in more accurate component positioning with fewer outliers. It is not known whether image-based or image-free-systems are preferable and if navigation for only one component leads to equal accuracy in leg alignment than navigation of both components. We evaluated the results of total knee arthroplasties performed with femoral navigation. We studied 90 knees in 88 patients who had conventional total knee arthroplasties, image-based total knee arthroplasties, or total knee arthroplasties with image-free navigation. We compared patients' perioperative times, component alignment accuracy, and short-term outcomes. The total surgical time was longer in the image-based total knee arthroplasty group (109 +/- 7 minutes) compared with the image-free (101 +/- 17 minutes) and conventional total knee arthroplasty groups (87 +/- 20 minutes). The mechanical axis of the leg was within 3 degrees of neutral alignment, although the conventional total knee arthroplasty group showed more (10.6 degrees ) variance than the navigated groups (5.8 degrees and 6.4 degrees , respectively). We found a positive correlation between femoral component malalignment and the total mechanical axis in the conventional group. Our results suggest image-based navigation is not necessary, and image-free femoral navigation may be sufficient for accurate component alignment.
Cement augmentation using PMMA cement is known as an efficient treatment for osteoporotic vertebral compression fractures with a rapid release of pain in most patients and prevention of an ongoing kyphotic deformity of the vertebrae treated. However, after a vertebroplasty there is no chance to restore vertebral height. Using the technique of kyphoplasty a certain restoration of vertebral body height can be achieved. But there is a limitation of recovery due to loss of correction when deflating the kyphoplastic ballon and before injecting the cement. In addition, the instruments used are quite expensive. Lordoplasty is another technique to restore kyphosis by indirect fracture reduction as it is used with an internal fixateur. The fractured and the adjacent vertebrae are instrumented with bone cannulas bipediculary and the adjacent vertebrae are augmentated with cement. After curing of the cement the fractured vertebra is reduced by applying a lordotic moment via the cannulas. While maintaining the pretension the fractured vertebra is reinforced. We performed a prospective trial of 26 patients with a lordoplastic procedure. There was a pain relief of about 87% and a significant decrease in VAS value from 7.3 to 1.9. Due to lordoplasty there was a significant and permanent correction in vertebral and segmental kyphotic angle about 15.2°and 10.0°, respectively and also a significant restoration in anterior and mid vertebral height. Lordoplasty is a minimal invasive technique to restore vertebral body height. An immediate relief of pain is achieved in most patients. The procedure is safe and cost effective.
Background and purpose Computer navigation in total knee arthroplasty is somewhat controversial. We have previously shown that femoral component positioning is more accurate with computed navigation than with conventional implantation techniques, but the clinical impact of this is unknown. We now report the 5-year outcome of our previously reported 2-year outcome study.Methods 78 of initially 84 patients (80 of 86 knees) were clinically and radiographically reassessed 5 (5.1–5.9) years after conventional, image-based, and image-free total knee arthroplasty. The methodology was identical to that used preoperatively and at 2 years, including the Knee Society score (KSS) and the functional score (FS), and AP and true lateral standard radiographs.Results Although a more accurate femoral component positioning in the navigated groups was obtained, clinical outcome, number of reoperations, KSS, FS, and range of motion were similar between the groups.Interpretation The increased costs and time for navigated techniques did not translate into better functional and subjective medium-term outcome compared to conventional techniques.
Background: The treatment of displaced intra-articular calcaneal fractures remains a challenge and the optimal approach is still controversial. The main reason to avoid the extended lateral approach is the high complication rate due to wound healing problems. We report on 16 years of experience with a standardized limited open reduction and internal fixation technique. Methods: Between 2001 and 2017, we prospectively followed 240 consecutive patients operatively treated for a displaced intra-articular calcaneal fracture. Patients with open, multiple, bilateral, extra-articular, and Sanders IV fractures and those lost to follow-up were excluded. A lateral subtalar approach was used, with a cast for 8 weeks and full weightbearing allowed after 12 weeks. Follow-up examinations were scheduled until 24 months. Subjective and clinical assessment included gait abnormality, subtalar and ankle range of motion, and stability and alignment. The American Orthopaedic Foot & Ankle Society (AOFAS) hindfoot score was calculated. Alignment was analyzed on standard radiographs. In total, 131 patients were excluded. The remaining 109 patients were followed for a minimum of 24 months (34.4 ± 14.2 [range, 24-102] months). Results: The mean AOFAS score was 87 ± 13 (range, 32-100). “Excellent” and “good” results, as well as hindfoot motion with “normal/mild” and “moderate” restrictions, were seen in 80% of patients. Early reoperations were performed for insufficient reduction (2 patients), delayed wound healing (debridement, 3 patients), and hematoma (1 patient). Late revisions were arthrodesis (3 patients), medializing calcaneal osteotomy (1 patient), and implant removal (53 patients; 49%). Conclusion: The presented approach has remained unmodified for 16 years and resulted in consistently good functional results. The main disadvantage was the high rate of heel screw removal. Level of Evidence: Level IV, retrospective case series.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.