Background and purposeFixation of unstable trochanteric fractures is challenging. Application of a circumferential wire may facilitate bone contact and avoid postoperative fracture displacement. However, the use of circumferential wires remains controversial due to possible disturbance of the blood supply to the underlying bone. We evaluated the results of applied circumferential wires, concentrating mainly on complications and reoperations.Patients and methods60 patients with unstable trochanteric fractures and use of circumferential wires (1 or more) and an intramedullary nail were included from 2 centers. We retrospectively assessed complications and reoperation rates within the first postoperative year.ResultsIn 37 of the 60 patients, 2 or more circumferential wires were used. Anatomic reduction was achieved in 24 of the patients and a total cortical displacement of ≤ 10 mm was achieved in 26 other patients. 6 of the 43 patients with radiographic audit after 12 weeks sustained a subsequent fracture displacement of more than 5 mm. 4 patients underwent reoperation: 1 due to deep infection, 1 due to technical failure during osteosynthesis, 1 had a screw cut out, and 1 sustained a new fracture following a new fall.InterpretationApplication of circumferential wires as a supplement to intramedullary nails in unstable trochanteric fractures is an option as it provides good primary reduction which, in most patients, is maintained over time—with no apparent increase in reoperation rate. Based on our results and on other reports, the use of circumferential wires does not appear to be harmful as sometimes claimed.
The role of uncemented fully hydroxyapatite coated hemiarthroplasties for the treatment of displaced femoral neck fractures remains unclear. We investigated if complications, reoperations and mortality differed from that of cemented hemiarthroplasties. The study groups consisted of 78 cemented and 97 uncemented, hydroxyapatite coated hemiarthroplasties with minimum 1 year follow-up. The dislocation rate was 3% in both groups (p=0.84). Proximal femoral fracturing occurred in 1% in the cemented group and in 4% in the uncemented group (p=0.26). Reoperations were performed following 4% of procedures in the cemented group and following 2% of procedures in the uncemented group (p=0.48). Mortality rates did not differ statistically significant between groups. Outcomes were comparable. Introduction of an uncemented hydroxyapatite coated hemiarthroplasty for treatment of displaced femoral neck fractures can be recommended.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.