ObjectiveTo identify and compare patient and procedural variables that are associated with a high radiation dose exposure and worse clinical outcomes between transradial arterial (TRA) and transfemoral arterial (TFA) approaches.DesignThis was a retrospective analysis.SettingA community hospital during the initial phase of adopting a TRA-first approach.ParticipantsA resultant 215 subjects who only underwent diagnostic cerebral angiograms (DCA) after excluding all therapeutic procedures and patients under 18 years.InterventionsOnly DCA from 1 May 2018 to 31 January 2021.Main outcome measuresWe compared radiation exposure parameters (total fluoroscopy time (FT), total radiation dose (TD) and dose area product (DAP), number of vessels injected and Patient-Reported Global Health Physical and Mental Outcome Scores (PROGHS) at 30 days postprocedure between groups.ResultsFT was significantly greater in TRA compared with TFA (p<0.001). In addition, TRA had a significantly higher TD (p=0.002) and DAP (p=0.005) when compared with TFA. Analysis of only 6-vessel DCAs also showed that TRA had a significantly higher FT, DAP and TD in comparison to TFA. Despite observing a longer FT in TRA, results showed fewer vessels injected and a notably lower success rate in acquiring a 6-vessel DCA using the TRA. Further analysis of the effect of vessel number on FT using general linear models showed that with every increase of one vessel, the FT increases by 2.2 min for TRA (p<0.001; 95% CI 1.03 to 3.36) and by 1.3 min for TFA (p<0.001; 95% CI 0.72 to 1.83). There was no significant difference between groups in PROGHS mental and physical t-scores at 30 days postprocedure, even though our cohort showed a significantly greater percentage of TRA procedures done in the outpatient setting.ConclusionsAdopting a TRA first approach for DCAs may be initially associated with a higher radiation dose for the patient. Better strategies and devices are needed to mitigate this effect.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.