The FRANCE TAVI registry provided reassuring data regarding trends in TAVR performance in an all-comers population on a national scale. Nonetheless, given that TAVR indications are likely to expand to patients at lower surgical risk, concerns remain regarding potentially life-threatening complications and pacemaker implantation. (Registry of Aortic Valve Bioprostheses Established by Catheter [FRANCE TAVI]; NCT01777828).
In the previous issue of Critical Care, Muller and colleagues investigated whether respiratory variation in inferior vena cava diameter (ΔIVC) could be a useful predictor of fluid responsiveness in spontaneously breathing patients. The study concludes that accuracy was not very good and therefore that this parameter should be used with caution in these patients. There is still confusion about the meaning of IVC respiratory variations, whether the patient is spontaneously breathing or mechanically ventilated. In this brief commentary, we try to summarize as clearly as possible the significance of IVC variation in different clinical settings.
IntroductionOur aims in this study were to report changes in the ratio of alveolar dead space to tidal volume (VDalv/VT) in the prone position (PP) and to test whether changes in partial pressure of arterial CO2 (PaCO2) may be more relevant than changes in the ratio of partial pressure of arterial O2 to fraction of inspired O2 (PaO2/FiO2) in defining the respiratory response to PP. We also aimed to validate a recently proposed method of estimation of the physiological dead space (VDphysiol/VT) without measurement of expired CO2.MethodsThirteen patients with a PaO2/FiO2 ratio < 100 mmHg were included in the study. Plateau pressure (Pplat), positive end-expiratory pressure (PEEP), blood gas analysis and expiratory CO2 were recorded with patients in the supine position and after 3, 6, 9, 12 and 15 hours in the PP. Responders to PP were defined after 15 hours of PP either by an increase in PaO2/FiO2 ratio > 20 mmHg or by a decrease in PaCO2 > 2 mmHg. Estimated and measured VDphysiol/VT ratios were compared.ResultsPP induced a decrease in Pplat, PaCO2 and VDalv/VT ratio and increases in PaO2/FiO2 ratios and compliance of the respiratory system (Crs). Maximal changes were observed after six to nine hours. Changes in VDalv/VT were correlated with changes in Crs, but not with changes in PaO2/FiO2 ratios. When the response was defined by PaO2/FiO2 ratio, no significant differences in Pplat, PaCO2 or VDalv/VT alterations between responders (n = 7) and nonresponders (n = 6) were observed. When the response was defined by PaCO2, four patients were differently classified, and responders (n = 7) had a greater decrease in VDalv/VT ratio and in Pplat and a greater increase in PaO2/FiO2 ratio and in Crs than nonresponders (n = 6). Estimated VDphysiol/VT ratios significantly underestimated measured VDphysiol/VT ratios (concordance correlation coefficient 0.19 (interquartile ranges 0.091 to 0.28)), whereas changes during PP were more reliable (concordance correlation coefficient 0.51 (0.32 to 0.66)).ConclusionsPP induced a decrease in VDalv/VT ratio and an improvement in respiratory mechanics. The respiratory response to PP appeared more relevant when PaCO2 rather than the PaO2/FiO2 ratio was used. Estimated VDphysiol/VT ratios systematically underestimated measured VDphysiol/VT ratios.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.