BackgroundSelection of the most appropriate treatment to obtain the lowest morbidity, mortality, and recurrence rates is mandatory for hydatid disease of the liver. This study evaluated the results of laparoscopic treatment (compared with the open approach) in the context of a 10-year single-institution experience.MethodsBetween January 1998 and January 2008, 333 patients with hydatid disease of the liver underwent surgery in the authors’ department. Only the following aspects were considered as selection criteria for laparoscopic surgery: liver cyst not located in segment 1 or 7, with corticalization on the surface and no evidence of intrabiliary rupture. Of 62 patients who underwent laparoscopic treatment, 3 required conversion to open surgery. The remaining 59 patients (group 1) were analyzed. During the same period, 271 patients with hepatic hydatid disease underwent conventional surgery, but only 172 records were compatible with the criteria for the laparoscopic approach and the respective patients were retrospectively reviewed (group 2).ResultsConversion to open surgery occurred in three cases (4.84 %). The mean cyst diameter was 6.62 cm (range, 2–15 cm) in group 1 and 7.23 cm (range, 2–18 cm) in group 2 (p = 0.699). The mean operative time was 72 min (range, 45–140 min) in group 1 and 65 min (range, 35–120 min) in group 2 (p < 0.001). The general complication rate and abdominal wound complication rate were respectively 0 % and 0 % in group 1 (p = 0.023) compared with 5.23 and 8.72 % in group 2 (p = 0.015). The mean hospital stay was 6.42 days (range, 1–21 days) in group 1 and 11.7 days (range, 4–80 days) in group 2 (p < 0.001). The mean follow-up period was 24.2 months (range, 6–32 months) in group 1 and 28.4 months (range, 6–40 months) in group 2. No recurrences were observed in either group during this period.ConclusionLaparoscopic surgery provides a safe and efficacious approach for almost all types of hepatic hydatid cysts. Large, prospective, randomized trials are needed to confirm its superiority.
Aims: To report on the long-term impact of tumor and non-tumor related parameters on local recurrence, distant recurrence and survival in patients with naïve or recurrent type hepatocellular carcinoma (HCC) treated by radiofrequency ablation (RFA).Methods: We performed 240 RFA sessions on 133 patients with 156 HCC nodules developed on a background of liver cirrhosis and analyzed the outcomes.Results: Contrast-enhanced ultrasound performed one month after RFA showed complete ablation in 119 out of 133 (89.65%) patients. With a median follow-up of 46 months, 3-, 5- and 7-year survival rates were 61.7%, 35.7%, and 22.6%, respectively. Previous ethanol injection and histological grade were significantly related to local tumor progression. Child-Pugh class, incomplete ablation, histological grade, previous ethanol injection, alpha-fetoprotein level before the treatment, and local recurrence were all significantly related to distant recurrence. Multivariate analysis demonstrated that age, Child-Pugh class, distant recurrence and multiple incomplete ablations were significantly related to survival.Conclusion: Radiofrequency ablation could be locally curative for HCC, resulting in a survival longer than 7 years. Previous ethanol injection and incomplete ablations were strongly associated with poor outcomes.
Aim: Percutaneous radiofrequency (RFA) and microwave ablation (MWA) are currently the best treatment options forpatients with liver metastases (LM) who cannot undergo a liver resection procedure. Presently, few studies have evaluated theefficacy of tumor ablation in beginner’s hands but none at all in hepatic metastasis. Our aim was to report the initial experiencewith ultrasound as a tool to guide tumor ablation in a low volume center with no experience in tumor ablation.Material and methods: We conducted a retrospective cohort study, on a series of 61 patients who had undergone percutaneous US-guided ablations for 82 LM between 2010 and 2015. Long term outcome predictors were assessed using univariate and multivariate analysis.Results: Complete ablation was achieved in 86.9% of cases (53/61). All MWA sessions (20/20) attained ablation margins >5mm, compared to 79% (49/62) for RFA sessions (p=0.031). Ablation time was significantly shorter for MWA, with a median duration of 10 minutes (range: 6-12) vs. 14 minutes (range: 10-19.5, p=0.003). There was no statistically significant difference in local tumor progression (LTP)-free survival rates between MWA and RFA (p=0.154). On univariate analysis, significant predictors for local recurrence were multiple metastases (p=0.013) and ablation margins <5 mm (p<.001), both retaining significance on multivariate analysis. Significant predictors for distant recurrence on both univariate and multivariate analysis were multiple metastases (p<0.001) and non-colorectal cancer metastases (p<0.05).Conclusion: A larger than 5 mm ablation size is critical for local tumor control. We favor the use of MWA due to its ability to achieve ablation in significantlyshorter times with less incomplete ablations.
To investigate the effects of PEG-coated gold nanoparticles on ablation zone volumes following in vivo radiofrequency ablation of porcine liver. This prospective study was performed following institutional animal care and committee approval was used. Radiofrequency ablations were performed in the livers of ten Sus scrofa domesticus swines. During each ablation, 10 mL (mL) of Peg-coated gold nanoparticles at two different concentrations (0.5 mg/mL and 0.01 mg/mL) were injected through the electrode channel into the target zone. For the control group, 10 mL of physiological saline was used. Five to ten minutes after each ablation, contrast enhanced ultrasound (CEUS) was performed to evaluate the volume of the coagulation zone. On day five we performed another CEUS and the animals were sacrificed. Treated tissues were explanted for quantification of the ablation zones’ volumes. Hematoxylin and eosin (H&E) staining was also performed for histologic analysis. A total of 30 ablations were performed in the livers. The mean coagulation zone volume as measured by CEUS on day 5 after RFA was: 21.69 ± 3.39 cm3, 19.22 ± 5.77 cm3, and 8.80 ± 3.33 cm3 for N1, N2 and PS respectively. The coagulation zone volume after N1 and N2 treatments was significantly higher compared to PS treatment (p < 0.001 and p = 0.025 respectively). There was no difference between N1 and N2 treatment (p = 0.60). In our proof-of concept, pilot study we have shown for the first time that when injected directly into the target tissue during RFA, gold nanoparticles can substantially increase the coagulation zone.
BackgroundUnique properties exhibited by nanoparticles makes them great candidates for applications in physics, chemistry, biology, material science and medicine. The biological applications of water-soluble gold nanoparticles range from contrast agents, delivery vehicles to therapeutics. Notch signaling is a complex network that orchestrates cell fate decisions, which involves proliferation, migration, differentiation and cell death in organisms ranging from insects to humans. Studies have showed that a correct orientation of the Jag-1 signalling protein on the substrates proves to be of great importance when promoting Jagged-1 Notch interactions, also the availability of the ligands, super cedes the importance of their concentration.ResultsThe aim of the present study was to synthetize a Jag-1 functionalized nanocarrier, which would promote an efficient interaction between the Jag-1 peptide and the Notch receptor. To this end, two routes for gold nanoparticle-peptide assembly were investigated, and the synthetized bio-nanostructures were characterized and compared by means of UV–Vis, FT-IR, DLS and AFM techniques.ConclusionsWe have obtained a stable, monodisperse, hetero-functionalized GNP-PEG-JAG-1 bio-nanostructure for Notch pathway activation applications.Electronic supplementary materialThe online version of this article (doi:10.1186/s12951-015-0100-x) contains supplementary material, which is available to authorized users.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.