Factors influencing effectiveness of automated comparisons, test-fired bullets, and cartridge cases from 0.38 Special revolvers were logged into the Evofinder Ballistic ID System. Tests were performed as follows: First test correlated test-fires of the same type, second test compared different types of ammunition components, third test replicated the second test in a larger database, and fourth test replicated the third test with students having no previous firearm identification experience. System effectiveness with projectiles in the first test was 0.89. With cartridge cases, effectiveness was 0.79 with combined results, but analysis of separate results by breech face and firing pin revealed low effectiveness by breech face (0.40). In the second, third, and fourth tests, effectiveness with projectiles were 0.61, 0.51, and 0.44. In addition, these tests had effectiveness with cartridge cases equivalent to 0.55, 0.43, and 0.44. Results are useful to establish routine protocols, system improvements, or comparative assessment of other electronic systems.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.