Mechanical circulatory support devices have been increasingly used for long-term support. We reviewed outcomes in all patients supported with a SynCardia total artificial heart (TAH) for more than 1 year to assess its safety in long-term support. As of December 2011, all 47 patients who received the TAH from 10 centers worldwide were included in this retrospective study. Clinical data were collected on survival, infections, thromboembolic and hemorrhagic events, device failures, and antithrombotic therapy. The mean age of patients was 50 ± 1.57 years, the median support time was 554 days (range 365-1373 days). The primary diagnosis was dilated cardiomiopathy in 23 patients, ischemic in 15, and "other" in 9. After a minimum of 1 year of support, 34 patients (72%) were successfully transplanted, 12 patients (24%) died while on device support, and 1 patient (2%) is still supported. Five patients (10%) had a device failure reported. Major complications were as follows: systemic infections in 25 patients (53%), driveline infections in 13 patients (27%), thromboembolic events in 9 patients (19%), and hemorrhagic events in 7 patients (14%). SynCardia TAH has proven to be a reliable and effective device in replacing the entire heart. In patients who reached a minimum of 1 year of support, device failure rate is acceptable and only in two cases was the leading cause of death. Infections and hemorrhagic events were the major causes of death. Patients who remain supported beyond 1 year are still likely to survive to transplantation.
Methylene blue (MB) has received much attention in the perioperative and critical care literature because of its ability to antagonize the profound vasodilation seen in distributive (also referred to as vasodilatory or vasoplegic) shock states. This review will discuss the pharmacologic properties of MB and review the critical care, liver transplantation, and cardiac anesthesia literature with respect to the efficacy and safety of MB for the treatment of shock. Although improved blood pressure has consistently been demonstrated with the use of MB in small trials and case reports, better oxygen delivery or decreased mortality with MB use has not been demonstrated. Large randomized controlled trials are still necessary to identify the role of MB in hemodynamic resuscitation of the critically ill.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.